Evidence map›Paper›PMID 33073266›Full record

ArticleProceedings : Annual International Computer Software and Applications Conference. COMPSAC2020

Regularization of Deep Neural Networks for EEG Seizure Detection to Mitigate Overfitting.

Mohammed Saqib, Yuanda Zhu, May Dongmei Wang, Brett Beaulieu-Jones

Open access · greenAbstract read
In one paragraph

Article in Proceedings : Annual International Computer Software and Applications Conference. COMPSAC, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.3field-weighted citation impact, top 44% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 9 citations in OpenAlex.

  1. Review
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 2 institutions in 1 country.

Mohammed SaqibBiomedical Engineering, Georgia Institute of Technology, Atlanta, GA.
Yuanda ZhuElectrical Engineering, Georgia Institute of Technology, Atlanta, GA.
May Dongmei WangBiomedical Engineering, Georgia Institute of Technology, Atlanta, GA.
Brett Beaulieu-JonesDepartment of Biomedical Informatics, Harvard Medical School, Boston, MA.
Georgia Institute of Technology · USHarvard University · US

Funding

RESEARCH TRAINING-MEDICAL INFORMATICS 90T15LM007092 · NLM · HARVARD UNIVERSITY (SCH OF PUBLIC HLTH) · PI Nils Gehlenborg · 1992 to 2026
$32.8M
Tissue and Animal UseU54CA119338 · NCI · EMORY UNIVERSITY · PI NIE, SHUMING · 2005 to 2009
$18.4M
TrainingU54HG007963 · NHGRI · HARVARD MEDICAL SCHOOL · PI KOHANE, ISAAC S. · 2014 to 2018
$18.3M
NCI NIH HHS U54 CA119338NHGRI NIH HHS U54 HG007963NLM NIH HHS T15 LM007092
6 · The paper itself

Abstract

Seizure detection is a major goal for simplifying the workflow of clinicians working on EEG records. Current algorithms can only detect seizures effectively for patients already presented to the classifier. These algorithms are hard to generalize outside the initial training set without proper regularization and fail to capture seizures from the larger population. We proposed a data processing pipeline for seizure detection on an intra-patient dataset from the world's largest public EEG seizure corpus. We created spatially and session invariant features by forcing our networks to rely less on exact combinations of channels and signal amplitudes, but instead to learn dependencies towards seizure detection. For comparison, the baseline results without any additional regularization on a deep learning model achieved an F1 score of 0.544. By using random rearrangements of channels on each minibatch to force the network to generalize to other combinations of channels, we increased the F1 score to 0.629. By using random rescale of the data within a small range, we further increased the F1 score to 0.651 for our best model. Additionally, we applied adversarial multi-task learning and achieved similar results. We observed that session and patient specific dependencies were causing overfitting of deep neural networks, and the most overfitting models learnt features specific only to the EEG data presented. Thus, we created networks with regularization that the deep learning did not learn patient and session-specific features. We are the first to use random rearrangement, random rescale, and adversarial multitask learning to regularize intra-patient seizure detection and have increased sensitivity to 0.86 comparing to baseline study.