Evidence map›Paper›PMID 33070456›Full record

ArticleJournal of applied clinical medical physics2020

Dosimetric and mechanical equivalency of Varian TrueBeam linear accelerators.

Mohammed Ghazal, Lars Södergren, Mathias Westermark, Julia Söderström, Tobias Pommer

Open access · goldAbstract read
In one paragraph

Article in Journal of applied clinical medical physics, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed
1.8field-weighted citation impact, top 15% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

9 citing papers in PubMed, 15 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 1 institution in 1 country.

Mohammed GhazalDepartment of Medical Radiation Physics and Nuclear Medicine, Karolinska University Hospital, Stockholm, Sweden.
Lars SödergrenDepartment of Medical Radiation Physics and Nuclear Medicine, Karolinska University Hospital, Stockholm, Sweden.
Mathias WestermarkDepartment of Medical Radiation Physics and Nuclear Medicine, Karolinska University Hospital, Stockholm, Sweden.
Julia SöderströmDepartment of Medical Radiation Physics and Nuclear Medicine, Karolinska University Hospital, Stockholm, Sweden.
Tobias PommerDepartment of Medical Radiation Physics and Nuclear Medicine, Karolinska University Hospital, Stockholm, Sweden.
Karolinska University Hospital · SE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeTo investigate and improve the level of equivalency of Varian TrueBeam linear accelerators (linacs) in energy-, dosimetric leaf gap- (DLG) and jaw calibration.

methodsEight linacs with four photon energies: 6 MV, 6 MV FFF, 10 MV FFF, and 15 MV, and three electron energies (on two linacs): 6, 9, and 12 MeV were commisioned and beam-matched. Initially, symmetry of lateral profiles was calibrated for maximum field size. Energy-matching was then performed for photons by adjusting diagonal profiles at maximum field size and depth of maximum dose to coincide with the reference linac, and for electrons by matching the range at percentage depth of ionization of 90%, 80%, and 50%. Calibration of DLG was performed for 6 MV and evaluated among the linacs. The relationship between DLG and the Gap value was investigated. A method using electronic portal imaging device (EPID) was developed and implemented for jaw calibration.

resultsSymmetry calibration for photons (electrons) was within 1% (0.7%), further improving the vendor's acceptance criteria. Photon and electron energy-matching was within 0.5% and 0.1 mm, respectively. Calibration of DLG was within 0.032 mm among the linacs and utilizing the relationship between DLG and the Gap value resulted in an empirical calibration method which was implemented to simplify DLG adjustment. Using EPID-based method of calibration, evaluation of the jaw-positioning among the linacs for 30 cm × 30 cm field size was within 0.4 mm and in the junction area within 0.2 mm. Dose delivery error of VMAT-plans were at least 99.2% gamma pass rate (1%, 1 mm).

conclusionsHigh level of equivalency, beyond clinically accepted criteria, of TrueBeam linacs could be achieved which reduced dose delivery systematic errors and increased confidence in interchanging patients among linacs.

Indexed as

Particle AcceleratorsRadiometryCalibrationElectronsHumansPhotonsbeam-matchingDLG and jaw calibrationenergy-matching

Identifiers

PMID33070456
PMCPMC7769408
OpenAlexW3093017421

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.