ArticleSensors (Basel, Switzerland)2020
Development of a High-Resolution All-Fiber Homodyne Laser Doppler Vibrometer.
Article in Sensors (Basel, Switzerland), 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Multipoint Wave Measurement in Tuned Liquid Damper Using Laser Doppler Vibrometer and Stepwise Rotating Galvanometer Scanner.Sensors (Basel, Switzerland) · 2021Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
Abstract
Based on the homodyne detection, a compact and cost-effective all-fiber laser Doppler vibrometer (LDV) with high resolution is presented. For the signal processing, the discrimination algorithm combined with the nonorthogonal correction is applied. The algorithm corrects the quadrature imbalance and other nonlinearity. In the calibration experiment, with the glass pasted on a piezoceramic transducer (PZT), the velocity resolution of 62 nm/s at 4 kHz and displacement resolution of 2.468 pm are achieved. For the LDV-based acousto-optic communication, the minimum detectable sound pressure level (SPL) reached 0.12 Pa under the hydrostatic air-water surface. The results demonstrate that the designed homodyne LDV has a low system background noise and can offer high precision in the vibration measurement.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.