ArticlePolymers2020
Polyethylene-Based Knee Spacer for Infection Control: Design Concept and Pre-Clinical In Vitro Validations.
Article in Polymers, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed, 6 citations in OpenAlex.
- Oxidized Zirconium Bearing Surface Failure in Total Knee Arthroplasty: A Unique Case Report of Isolated Medial Compartment with Catastrophic Results.Journal of orthopaedic case reports · 2023Article
- Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 3 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Antibiotic-loaded polymethyl methacrylate (PMMA) has been widely applied in the treatment of knee periprosthetic joint infections. However, problems with antibiotic-loaded PMMA-based spacers, such as structural fracture and implant dislocation, remain unresolved. A novel polyethylene-based spacer, designed with an ultra-congruent articulating surface and multiple fenestrations, was introduced in the current study. Validation tests for biomechanical safety, wear performance, and efficacy of antibiotic cement were reported. During cycle fatigue testing, no tibial spacer failures were observed, and less wear debris generation was reported compared to commercial PMMA-based spacers. The volumetric wear of the novel spacer was within the safety threshold for osteolysis-free volumetric wear. An effective infection control was demonstrated despite the application of lesser antibiotic cement in the 30-day antibiotic elution test. The tube dilution test confirmed adequate inhibitory capabilities against pathogens with the loaded antibiotic option utilized in the current study. The novel polyethylene-based knee spacer may offer sufficient biomechanical safety and serve as an adequate carrier of antibiotic-loaded cement for infection control. Further clinical trials shall be conducted for more comprehensive validation of the novel spacer for practical application.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.