ArticleOrthopaedic surgery2020
Management of Medial Collateral Ligament Insufficiency During Total Knee Arthroplasty with a Screw and Rectangular Spiked Washer: A Case Series of 14 Patients.
Article in Orthopaedic surgery, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
4 citing papers in PubMed, 1 synthesis or guideline pooled it, 3 citations in OpenAlex.
- Impact of intraoperative medial collateral ligament injury on outcomes after total knee arthroplasty: a meta-analysis and systematic review.Journal of orthopaedic surgery and research · 2021Pooled it
- A New Sensorized Approach Based on a DeepLabCut Model and IR Thermography for Characterizing the Thermal Profile in Knees During Exercise.Sensors (Basel, Switzerland) · 2024Article
- Management of Iatrogenic Medial Collateral Ligament Injury in Primary Total Knee Arthroplasty: A Systematic Review.The archives of bone and joint surgery · 2024Review
- Prostheses option in revision total knee arthroplasty, from the bench to the bedside: (1) basic science and principles.EFORT open reviews · 2022Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
9 authors at 3 institutions in 2 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
objectiveTo describe the technique of primary repair of medial collateral ligament (MCL) insufficiency using a screw and rectangular spiked washer in a case series of 14 patients.
methodsFourteen patients undergoing MCL repair by a screw and rectangular spiked washer during TKA between March 2018 and March 2019 were retrospectively reviewed. Among them, half injuries were avulsion of the femoral origin, and the other half were MCL laxity. There were 12 women and two men included in the study, with an average age of 63.6 years (range, 49-79 years) at the time of surgery. This series were followed up with a focus on range of motion (ROM), coronal alignment, Hospital for Special Surgery (HSS) knee scores, their subjective sense of joint instability, and related complications. At the last follow-up, function of the MCL was assessed by manually applying a valgus stress to the knee at both 0° and 30° of knee flexion.
resultsThe mean follow-up time for all patients was 15.6 months (range, 13-20 months). Repair of the MCL was successful in all patients. ROM improved from a mean of 70.7° ± 35.1° before surgery to 103.9° ± 6.8° at latest follow-up (P = 0.001). All patients were able to perform a half squat easily, but none were able to do full squatting. The mean preoperative HSS score was 43.6 ± 13.4 and increased to a mean of 85.6 ± 3.8 postoperatively (P < 0.001). The femorotibial angle improved from a mean of -3.22° ± 9.47° before surgery to a mean of 5.16° ± 3.14° at the final follow-up (P = 0.006). At the time of final follow-up, no patient required revision and manipulation under anesthesia following the index arthroplasty. No radiolucencies or migration were observed in association with the knee prostheses. No displacement of the screw and rectangular spiked washer was found. There were no clinical complications. No patient reported subjective instability of the knee. Upon physical examination, no patient was found to have laxity in the coronal plane in either 30° of flexion or full extension.
conclusionsThe screw and rectangular spiked washer is a simple and effective method for treating MCL sufficiency in TKA, and a study with a larger cohort and extended follow-up is requisite to claim its role in preventing coronal instability and component failure.