Evidence map›Paper›PMID 33050386›Full record

ArticleSensors (Basel, Switzerland)2020

A Stable Biotin-Streptavidin Surface Enables Multiplex, Label-Free Protein Detection by Aptamer and Aptamer-Protein Arrays Using Arrayed Imaging Reflectometry.

Alanna M Klose, Benjamin L Miller

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors.

Alanna M KloseDepartment of Dermatology, University of Rochester Medical Center, Rochester, NY 14642, USA.
Benjamin L MillerDepartment of Dermatology, University of Rochester Medical Center, Rochester, NY 14642, USA.ORCID 0000-0001-9168-8047

Funding

Adarza BioSystems N/A
6 · The paper itself

Abstract

While label-free multiplex sensor technology enables "mixing and matching" of different capture molecules in principle, in practice this has been rarely (if ever) demonstrated. To fill this gap, we developed protocols for the preparation of mixed aptamer-protein arrays on the arrayed imaging reflectometry (AIR) sensing platform using streptavidin as a common attachment point for both biotinylated proteins and aptamers. Doing so required overcoming the noted instability of dried streptavidin monolayers on surfaces. After characterizing this degradation, stable surfaces were obtained using a commercial microarray product. Microarraying through the layer of stabilizer then provided mixed aptamer-antibody arrays. We demonstrate that sensor arrays prepared in this manner are suitable for several probes (thrombin and TGF-β1 aptamers; avi-tagged protein) and targets.

Indexed as

Aptamers, NucleotideBiosensing TechniquesProtein Array AnalysisBiotinStreptavidinAptamers, NucleotideBiotinStreptavidinaptamerbiotinmicroarrayproteinreflectometrystreptavidin

Identifiers

PMID33050386
PMCPMC7650819

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.