Evidence map›Paper›PMID 33047230›Full record

SynthesisArchives of orthopaedic and trauma surgery2021

Bi-cruciate retaining total knee arthroplasty: a systematic literature review of clinical outcomes.

Christoph Kolja Boese, Stephen Ebohon, Christian Ries, Diarmuid De Faoite

Abstract readSystematic Review
PubMed Publisher
In one paragraph

Synthesis in Archives of orthopaedic and trauma surgery, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
10citing papers in PubMed, 1 pooled it
2.9field-weighted citation impact, top 9% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

10 citing papers in PubMed, 1 synthesis or guideline pooled it, 23 citations in OpenAlex.

  1. Pooled it
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Review
  9. Review
  10. Early results with a bicruciate-retaining total knee arthroplasty: a match-paired study.European journal of orthopaedic surgery & traumatology : orthopedie traumatologie · 2021
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 4 institutions in 3 countries.

Christoph Kolja BoeseDepartment of Orthopaedic and Trauma Surgery, University Hospital of Cologne, Cologne, Germany. Christoph.boese@uk-koeln.de.ORCID http://orcid.org/0000-0002-5050-9345
Stephen EbohonSmith + Nephew, Hull, UK.
Christian RiesDepartment of Orthopaedics, University Medical Center Hamburg-Eppendorf, Hamburg, Germany.
Diarmuid De FaoiteSmith + Nephew, Baar, Switzerland.
Smith & Nephew (Germany) · DESmith & Nephew (Switzerland) · CHSmith & Nephew (United Kingdom) · GBUniversität Hamburg · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Total knee arthroplasty (TKA) has been shown to have good long-term outcomes and survivorship. Nonetheless, dissatisfied patients are frequently reported in the literature. Bi-cruciate retaining total knee prostheses (BCR TKA) were designed to address the demand for more kinematically functional implants that better reconstruct natural knee kinematics. In BCR TKA, the anterior cruciate ligament (ACL) is preserved. Improved patient-reported outcomes and satisfaction levels are expected. This review aimed to summarize indications for and clinical outcomes of BCR TKA. A systematic literature review on BCR TKA was performed. 24 articles were included for data analysis. Indications covered osteoarthritis, inflammatory arthritis and others. The degree of deformity was often but not always limited to minor axial deformity and contractures: maximum acceptable varus/valgus deformity reached 10°-30° and flexion contractures of 15°-65°. ACL intactness was macroscopically examined intraoperatively in nine studies and clinically tested in ten studies (e.g., Lachmann Test, drawer-test). Objective and patient-reported outcome scores were reported for follow-up periods of up to 22 years. Survival rates varied significantly. For first generation implants, 22-year survival reached 82% while a second generation design was associated with 13.5% revision rate at 18 months. Reasons for varying outcomes were not clear and may be attributed to the implant itself, surgical techniques and patient specific variables including changed expectations and functional demand. The literature has not shown clear indications and guidelines for the use of BCR implants. The promising results of first generation BCR TKA designs may be optimized through improved implant designs in the future. Further studies are advocated to provide the necessary evidence of second generation BCR TKA designs.

Indexed as

Arthroplasty, Replacement, KneeBiomechanical PhenomenaHumansKneePatient Reported Outcome MeasuresTreatment OutcomeAnterior cruciate ligamentJoint replacementOsteoarthritisSystematic reviewTotal knee arthroplasty

Identifiers

PMID33047230
OpenAlexW3092627096

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.