Evidence map›Paper›PMID 33047176›Full record

Trial reportEuropean journal of orthopaedic surgery & traumatology : orthopedie traumatologie2021

Pronator quadratus repair after volar plate fixation in distal radial fractures: evaluation of the clinical and functional outcome and of the protective role on the flexor tendons-a randomized controlled study.

C K Goorens, P B De Keyzer, K Van Royen, S Provyn, J F Goubau

Abstract readRandomized Controlled Trial
PubMed Publisher
In one paragraph

Trial report in European journal of orthopaedic surgery & traumatology : orthopedie traumatologie, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
2.5field-weighted citation impact, top 10% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 13 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 2 institutions in 1 country.

C K GoorensRegionaal Ziekenhuis Tienen, Kliniekstraat 45, 3300, Tienen, Belgium. cgoorens@msn.com.
P B De KeyzerRegionaal Ziekenhuis Tienen, Kliniekstraat 45, 3300, Tienen, Belgium.
K Van RoyenUniversity Hospital Brussels, Vrije Universiteit Brussel, Laarbeeklaan 101, 1090, Brussels, Belgium.
S ProvynVrije Universiteit Brussel, Laarbeeklaan 101, 1090, Brussels, Belgium.
J F GoubauUniversity Hospital Brussels, Vrije Universiteit Brussel, Laarbeeklaan 101, 1090, Brussels, Belgium.
Vrije Universiteit Brussel · BEUniversitair Ziekenhuis Brussel · BE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The objective was to evaluate pronator quadratus (PQ) repair following volar plating of distal radial fractures on clinical and functional outcome, as well as flexor tendon friction, during the first 12 months in ideally positioned plates (Soong 0). Confounding factors like variation in plate positioning, anatomical consolidation of the fracture and associated lesions were excluded. Eighty patients were included with distal radius fractures treated by volar locking plate in Soong grade 0 position, who were randomized to group PQ repair and group no repair. Sixty-five patients completed the 1-year follow-up: group PQ repair (n = 35) and group no repair (n = 30). Primary outcomes included range of motion, grip strength, pain level and QuickDASH. Secondary outcomes included distance between flexor pollicis longus (FPL) and volar rim and the largest distance between FPL and plate (soft tissue thickness occupied by PQ), assessed by ultrasonography. Mobility, grip strength and QuickDASH revealed no significant differences, except extension was significantly higher only in first 3 months and radial deviation was significantly higher only at 6 weeks after PQ repair. Pain level was significantly lower after PQ repair only in the first 3 months. Distance between FPL and volar rim and the largest distance between FPL and plate were significantly higher after PQ repair. No friction contact between FPL and volar rim was measured in both groups at all measurement moments. Consequently, protective flexor tendon effect of PQ repair could consequently not be concluded. In conclusion, clinical and functional short term benefits, except improved wrist extension and reduced pain in the first 3 months, were not proven in this study. In Soong grade 0, PQ repair is probably not necessary to prevent flexor tendon pathology. In Soong grade 1 or 2, this is still to be investigated. LEVEL OF EVIDENCE: 2.

Indexed as

Radius FracturesBone PlatesFracture Fixation, InternalHumansTendonsWrist JointDistal radiusFPLPQPronator quadratus repairVolar plateVolar rimWatershed line

Identifiers

PMID33047176
OpenAlexW3092087671

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.