Performance assessment of two motion management systems for frameless stereotactic radiosurgery.
Article in Strahlentherapie und Onkologie : Organ der Deutschen Rontgengesellschaft ... [et al], 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
8 citing papers in PubMed, 18 citations in OpenAlex.
- Outcomes and predictive factors after second stereotactic radiosurgery for refractory trigeminal neuralgia.Clinical and translational radiation oncology · 2025Article
- Stereotactic Radiosurgery in the Management of Brain Metastases: A Case-Based Radiosurgery Society Practice Guideline.Advances in radiation oncology · 2024Review
- Plan robustness analysis for threshold determination of SGRT-based intrafraction motion control in 3DCRT breast cancer radiation therapy.Radiation oncology (London, England) · 2023Article
- Optimal fractionation and timing of weekly cone-beam CT in daily surface-guided radiotherapy for breast cancer.Radiation oncology (London, England) · 2023Article
- Commissioning, clinical implementation, and initial experience with a new brain tumor treatment package on a low-field MR-linac.Journal of applied clinical medical physics · 2023Article
- Prerequisites for the clinical implementation of a markerless SGRT-only workflow for the treatment of breast cancer patients.Strahlentherapie und Onkologie : Organ der Deutschen Rontgengesellschaft ... [et al] · 2023Article
- Review
- Region of interest optimization for radiation therapy of breast cancer.Journal of applied clinical medical physics · 2021Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
14 authors at 5 institutions in 2 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
background/purposeFrameless stereotactic radiosurgery (SRS) requires dedicated systems to monitor patient motion in order to avoid inaccurate radiation delivery due to involuntary shifts. The purpose of this study is to assess the accuracy and sensitivity of two distinct motion monitoring systems used for frameless SRS.
methodsA surface image-guided system known as optical surface monitoring system (OSMS), and a fiducial marker-based system known as high definition motion management (HDMM) as part of the latest Gamma Knife Icon® were compared. A 3D printer-based cranial motion phantom was developed to evaluate the accuracy and sensitivity of these two systems in terms of: (1) the capability to recognize predefined shifts up to 3 cm, and (2) the capability to recognize predefined speeds up to 3 cm/s. The performance of OSMS, in terms of different reference surfaces, was also evaluated.
resultsTranslational motion could be accurately detected by both systems, with an accuracy of 0.3 mm for displacement up to 1 cm, and 0.5 mm for larger displacements. The reference surface selection had an impact on OSMS performance, with flat surface resulting in less accuracy. HDMM was in general more sensitive when compared with OSMS in capturing the motion, due to its faster frame rate, but a delay in response was observed with faster speeds. Both systems were less sensitive in detection of superior-inferior motion when compared to lateral or vertical displacement directions.
conclusionTranslational motion can be accurately and sensitively detected by OSMS and HDMM real-time monitoring systems. However, performance variations were observed along different motion directions, as well as amongst the selection of reference images. Caution is needed when using real-time monitoring systems for frameless SRS treatment.