Evidence map›Paper›PMID 33044976›Full record

ArticlePloS one2020

Experimental investigation into the effect of compliance of a mock aorta on cardiac performance.

Katie Cameron, Mouhammad El Hassan, Reza Sabbagh, Darren H Freed, David S Nobes

Abstract read
In one paragraph

Article in PloS one, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Review
  2. Article
  3. Periodic Flows in Microfluidics.Small (Weinheim an der Bergstrasse, Germany) · 2024
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Katie CameronDepartment of Biomedical Engineering, University of Alberta, Edmonton, Canada.
Mouhammad El HassanPrince Mohammad Bin Fahd University, Al-Khobar, Saudi Arabia.
Reza SabbaghDepartment of Mechanical Engineering, University of Alberta, Edmonton, Canada.ORCID 0000-0001-6446-6676
Darren H FreedDepartments of Surgery, Physiology & Biomedical Engineering, University of Alberta, Edmonton, Canada.
David S NobesDepartment of Mechanical Engineering, University of Alberta, Edmonton, Canada.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Demand for heart transplants far exceeds supply of donated organs. This is attributed to the high percentage of donor hearts that are discarded and to the narrow six-hour time window currently available for transplantation. Ex-vivo heart perfusion (EVHP) provides the opportunity for resuscitation of damaged organs and extended transplantation time window by enabling functional assessment of the hearts in a near-physiologic state. Present work investigates the fluid mechanics of the ex-vivo flow loop and corresponding impact on cardiac performance. A mechanical flow loop is developed that is analogous to the region of the EVHP system that mimics in-vivo systemic circulation, including the body's largest and most compliant artery, the aorta. This investigation is focused on determining the effect of mock aortic tubing compliance on pump performance. A custom-made silicone mock aorta was developed to simulate a range of in-vivo conditions and a physiological flow was generated using a commercial ventricular assist device (VAD). Monitored parameters, including pressure, tube distension and downstream velocity, acquired using time-resolved particle imaging velocimetry (PIV), were applied to an unsteady Bernoulli analysis of the flow in a novel way to evaluate pump performance as a proxy for cardiac workload. When compared to the rigid case, the compliant mock aorta case demonstrated healthier physiologic pressure waveforms, steadier downstream flow and reduced energetic demands on the pump. These results provide experimental verification of Windkessel theory and support the need for a compliant mock aorta in the EVHP system.

Indexed as

Models, CardiovascularAortaComplianceExtracorporeal CirculationHeart-Assist DevicesHeart TransplantationHemodynamicsHumansIn Vitro TechniquesOrgan PreservationPerfusionTissue and Organ ProcurementTissue Donors

Identifiers

PMID33044976
PMCPMC7549783

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.