ArticleIEEE transactions on ultrasonics, ferroelectrics, and frequency control2021
A 1.5-D Array for Acoustic Radiation Force (ARF)-Induced Peak Displacement-Based Tissue Anisotropy Assessment With a Row-Column Excitation Method.
Article in IEEE transactions on ultrasonics, ferroelectrics, and frequency control, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- A Rapid Prototyping Method for Sub-MHz Single-Element Piezoelectric Transducers by Using 3D-Printed Components.Sensors (Basel, Switzerland) · 2022Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
Abstract
Many biological tissues, including muscle or kidney, are mechanically anisotropic, and the degree of anisotropy (DoA) in mechanical properties is diagnostically relevant. DoA can be assessed either using the ratio of shear wave velocities (SWVs) or acoustic radio forced impulse (ARFI)-induced peak displacements (PD) measured longitudinal over transverse orientations. Whether using SWV or PD as a basis, DoA expressed as the ratio of values requires 90° transducer rotation when a linear array is employed. This large rotation angle is prone to misalignment errors. One solution is the use of a fully sampled matrix array for electronic rotation of point spread function (PSF). However, the challenges of matrix array are its high fabrication cost and complicated fabrication procedures. The cheaper and simpler alternative of matrix array is the use of a row-column array. A 3×64 elements 1.5-D array with a row-column excitation mode is proposed to assess DoA in mechanical properties using the PD ratio. Different numbers of elements in elevational and lateral directions were selected to have orthogonal ARFI excitation beams without rotating the transducer. A custom-designed flex circuit was used to fabricate the array with a simpler electrode connection than a fully sampled matrix array. The performance of the array was evaluated in Field II simulation and experiment. The output pressure was 0.57-MPa output under a 40- [Formula: see text] excitation with a -6-dB point spread dimension of 14×4 mm
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.