Evidence map›Paper›PMID 33043125›Full record

ArticleAdvanced materials technologies2019

Soft Material-Enabled, Active Wireless, Thin-Film Bioelectronics for Quantitative Diagnostics of Cervical Dystonia.

Young-Tae Kwon, Yongkuk Lee, Gamze Kilic Berkmen, Hyo-Ryoung Lim, Laura Scorr, H A Jinnah, Woon-Hong Yeo

Abstract read
In one paragraph

Article in Advanced materials technologies, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers.

0numbers the graph read from it
0cells of the map it votes in
12citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

12 citing papers in PubMed.

  1. An Exploratory, Randomized, Double-Blind Clinical Trial of Dipraglurant for Blepharospasm.Movement disorders : official journal of the Movement Disorder Society · 2024
    Trial
  2. Observational
  3. Article
  4. Beyond Flexible: Unveiling the Next Era of Flexible Electronic Systems.Advanced materials (Deerfield Beach, Fla.) · 2024
    Review
  5. Article
  6. Article
  7. Review
  8. Hold that pose: capturing cervical dystonia's head deviation severity from video.Annals of clinical and translational neurology · 2022
    Article
  9. Article
  10. Article
  11. Article
  12. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Young-Tae KwonGeorge W. Woodruff School of Mechanical Engineering, Institute for Electronics and Nanotechnology, Georgia Institute of Technology, Atlanta, GA 30332, USA.
Yongkuk LeeDepartment of Biomedical Engineering, Wichita State University, Wichita, KS 67260, USA.
Gamze Kilic BerkmenDepartments of Neurology and Human Genetics, School of Medicine, Emory University, GA 30322, USA.
Hyo-Ryoung LimGeorge W. Woodruff School of Mechanical Engineering, Institute for Electronics and Nanotechnology, Georgia Institute of Technology, Atlanta, GA 30332, USA.
Laura ScorrDepartments of Neurology and Human Genetics, School of Medicine, Emory University, GA 30322, USA.
H A JinnahDepartments of Neurology and Human Genetics, School of Medicine, Emory University, GA 30322, USA.
Woon-Hong YeoGeorge W. Woodruff School of Mechanical Engineering, Institute for Electronics and Nanotechnology, Georgia Institute of Technology, Atlanta, GA 30332, USA.

Funding

Dystonia Coalition- Pilot ProjectU54NS116025 · NINDS · EMORY UNIVERSITY · PI JINNAH, HYDER A · 2019 to 2023
$7.1M
Dystonia CoalitionU54TR001456 · NCATS · EMORY UNIVERSITY · PI JINNAH, HYDER A · 2015 to 2016
$2.5M
NCATS NIH HHS U54 TR001456NINDS NIH HHS U54 NS116025
6 · The paper itself

Abstract

Recent advances in flexible materials, nanomanufacturing, and system integration have provided a great opportunity to develop wearable flexible hybrid electronics for human healthcare, diagnostics, and therapeutics. However, existing medical devices still rely on rigid electronics with many wires and separate components, which hinders wireless, comfortable, continuous monitoring of health-related human motions. Here, we introduce advanced materials and system integration technologies that enable a soft, active wireless, thin-film bioelectronics. The low-modulus, highly flexible wearable electronic system incorporates a nanomembrane wireless circuit and functional chip components, enclosed by a soft elastomeric membrane. The bioelectronic system offers a gentle, seamless mounting on the skin, while offering a comfortable, highly sensitive and accurate detection of head movements. We utilize the wireless wearable hybrid system for quantitative diagnostics of cervical dystonia (CD) that is characterized by involuntary abnormal head postures and repetitive head movements, sometimes with neck muscle pain. A set of analytical and experimental studies shows a soft system packaging, hard-soft materials integration, and quantitative assessment of physiological signals detected by the SKINTRONICS.

Indexed as

Cervical dystoniaQuantitative digital assessmentSoft materials and packagingWearable flexible hybrid electronicsWireless quantification of movement

Identifiers

PMID33043125
PMCPMC7546326

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.