Evidence map›Paper›PMID 33037321›Full record

ArticleJournal of human hypertension2021

Results of a project to calibrate mercury sphygmomanometer blood pressure-measuring devices in Egypt.

Soliman Ghareeb, Ghada Youssef, Haytham Soliman Ghareeb, Hazem Abd El-Mageed, Muhammad H Mesalm, Remon Talaat, Alaaeldin Eltawil, Doaa M Hasan, M Mohsen Ibrahim

Open access · hybridAbstract read
In one paragraph

Article in Journal of human hypertension, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
1.3field-weighted citation impact, top 16% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 10 citations in OpenAlex.

  1. Article
  2. Spotlight on hypertension in the Middle-East.Journal of human hypertension · 2022
    Article
  3. The mercury sphygmomanometer: soon a museum piece!Journal of human hypertension · 2021
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 3 institutions in 1 country.

Soliman GhareebCardiology Department, Cairo University, Cairo, Egypt.
Ghada YoussefCardiology Department, Cairo University, Cairo, Egypt. ghadayoussef@kasralainy.edu.eg.ORCID 0000-0003-2020-1013
Haytham Soliman GhareebCardiology Department, El Fayoum University, El Fayoum, Egypt.
Hazem Abd El-MageedCardiology Department, Cairo University, Cairo, Egypt.
Muhammad H MesalmCardiology Department, Cairo University, Cairo, Egypt.
Remon TalaatIpsos Healthcare, Cairo, Egypt.
Alaaeldin EltawilNational Institute of Standards (NIS), Cairo, Egypt.
Doaa M HasanCardiology Department, Cairo University, Cairo, Egypt.
M Mohsen IbrahimCardiology Department, Cairo University, Cairo, Egypt.
Cairo University · EGFayoum University · EGNational Institute of Standards · EG

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Hypertension (HTN) is a common health problem and a major cardiovascular risk factor. Accurate measurement of blood pressure (BP) is mandatory for proper diagnosis and follow-up. The aim of this study was to evaluate the accuracy of mercury sphygmomanometer BP-measuring devices in public hospitals in Cairo, Egypt. Fifty public hospitals were included, and 10% of all mercury sphygmomanometer devices in each hospital were tested. Assessment included physical condition (e.g., mercury status, lid of the device, state of the rubber tubes), leakage rate, and calibration accuracy (as compared with a reference device). Devices were approved as accurate when they could successfully pass all three assessment tests. The total number of sphygmomanometer devices was 465. The overall pass rate was 1.3% (six devices). Twenty-five (5.2%) devices passed all of the physical tests, 50 (10.8%) passed the leakage test, and 50 (16.5%) passed the calibration accuracy test. There were 162 (34.8%) devices that showed a high leakage rate (>80 mmHg) and thus were not tested for calibration accuracy. In conclusion, most of the mercury sphygmomanometer devices in hospitals are neglected and not checked regularly for any errors. A plan should be made to gradually replace those failed devices with new, validated, and well-calibrated devices, preferably devices that do not contain mercury.

Indexed as

Blood Pressure DeterminationMercuryBlood PressureEgyptHumansSphygmomanometersMercury

Identifiers

PMID33037321
PMCPMC8502677
OpenAlexW3092208149

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.