Evidence map›Paper›PMID 33034779›Full record

ArticleEuropean journal of clinical microbiology & infectious diseases : official publication of the European Society of Clinical Microbiology2021

Effect of delayed entry on performance of the BACT/ALERT FAN PLUS bottles in the BACT/ALERT VIRTUO blood culture system.

Mary Adamik, Anne Hutchins, Jasmin Mangilit, Betsy Katzin, Heather Totty, Parampal Deol

Abstract read
In one paragraph

Article in European journal of clinical microbiology & infectious diseases : official publication of the European Society of Clinical Microbiology, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed.

  1. Direct MALDI-TOF MS identification and EUCAST RAST from positive blood cultures: impact on turnaround time in bloodstream infections.European journal of clinical microbiology & infectious diseases : official publication of the European Society of Clinical Microbiology · 2026
    Article
  2. Review
  3. Article
  4. The impact of optimizing microbial diagnosis processes on clinical and healthcare economic outcomes in hospitalized patients with bloodstream infections.European journal of clinical microbiology & infectious diseases : official publication of the European Society of Clinical Microbiology · 2024
    Article
  5. Article
  6. Review
  7. Article
  8. Impact of 24/7 loading of blood culture bottles in a new automated incubator on the diagnosis of bloodstream infections.European journal of clinical microbiology & infectious diseases : official publication of the European Society of Clinical Microbiology · 2021
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Mary AdamikbioMérieux, Inc., Durham, NC, USA.
Anne HutchinsbioMérieux, Inc., Durham, NC, USA. Anne.Hutchins@biomerieux.com.ORCID http://orcid.org/0000-0003-0680-3704
Jasmin MangilitbioMérieux, Inc., Durham, NC, USA.
Betsy KatzinbioMérieux, Inc., Durham, NC, USA.
Heather TottybioMérieux, Inc., Durham, NC, USA.
Parampal DeolbioMérieux, Inc., Durham, NC, USA.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Delayed entry of patient blood culture samples into a microbial detection system is unavoidable at times, due to off-shift staffing or transporting samples to centralized laboratories. Pre-incubation time and temperature of blood culture bottles are the most critical factors impacting recovery and detection of microorganisms. A total of 1377 BACT/ALERT® (BTA) Fastidious Antimicrobial Neutralization (FAN® PLUS) bottles (FA PLUS, FN PLUS, and PF PLUS) were tested after delayed entry times of 24 and 36 h at 20-25 °C (room temperature, RT) prior to loading into the BACT/ALERT® VIRTUO® microbial detection system (VIRTUO). Clinically relevant organisms were inoculated into bottles with 5-84 colony forming units (CFU) per bottle, and human blood (0 to 10 mL), and then loaded into the VIRTUO. When bottles were loaded without delay, a mean time to detection (TTD) of 9.6 h was observed. For delayed bottles, the TTD reported by the VIRTUO was added to the 24-h and 36-h delay times and resulted in average time to results of 32.5 h and 42.5 h, respectively. The FAN PLUS bottles in conjunction with the VIRTUO produced acceptable results when delays up to 24 h at 20-25 °C occur in loading.

Indexed as

Specimen HandlingBacteriological TechniquesBlood CultureCulture MediaHumansTime FactorsCulture MediaBACT/ALERT®Blood cultureDelayed entryPre-incubationSepsisVIRTUO®

Identifiers

PMID33034779
PMCPMC7979663

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked