ArticleHealth science reports2020
A wearable carotid Doppler tracks changes in the descending aorta and stroke volume induced by end-inspiratory and end-expiratory occlusion: A pilot study.
Article in Health science reports, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
11 citing papers in PubMed.
- Can carotid artery Doppler variations induced by the end-expiratory occlusion maneuver predict fluid responsiveness in septic shock patients?Critical care (London, England) · 2023Trial
- Wearable ultrasound: a review of core technologies and clinical applications in cardiovascular monitoring.Microsystems & nanoengineering · 2026Review
- Vascular Phenotyping with Photoacoustic and Ultrasound Imaging in Cardiovascular Disease: Recent Innovations.Current treatment options in cardiovascular medicine · 2026Review
- Correlation between carotid Doppler ultrasound-derived parameters and cardiac output measurements: a systematic review and meta-analysis.Quantitative imaging in medicine and surgery · 2025Article
- Carotid blood flow changes following a simulated end-inspiratory occlusion maneuver measured by ultrasound can predict hypotension after the induction of general anesthesia: an observational study.BMC anesthesiology · 2024Observational
- SmartWear body sensors for neurological and neurosurgical patients: A review of current and future technologies.World neurosurgery: X · 2024Review
- Recent advancements in critical care: Part I.Indian journal of anaesthesia · 2023Article
- Prediction of fluid responsiveness. What's new?Annals of intensive care · 2022Review
- The Doppler shock index measured by a wearable ultrasound patch accurately detects moderate-to-severe central hypovolemia during lower body negative pressure.Journal of the American College of Emergency Physicians open · 2021Article
- A wearable carotid Doppler tracks changes in the descending aorta and stroke volume induced by end-inspiratory and end-expiratory occlusion: A pilot study.Health science reports · 2020Article
- The Correlation between Carotid Artery Corrected Flow Time and Velocity Time Integral during Central Blood Volume Loss and Resuscitation.Journal of medical ultrasoundArticle
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
BACKGROUND AND
aimsTo test the feasibility of a novel, wearable carotid Doppler ultrasound to track changes in cardiac output induced by end-inspiratory and end-expiratory occlusion tests.
methodsWe observed the pattern of Doppler change of the common carotid artery during a simulated end-inspiratory and expiratory occlusion test (sEIOT/sEEOT) in 10, nonventilated, healthy subjects. Simultaneously, we measured the Doppler signal of the descending aorta using duplex ultrasound (Xario, Toshiba Medical Systems) and stroke volume (SV) using noninvasive pulse contour analysis (Clearsight, Edwards Lifesciences, Irvine, California).
resultsDuring sEIOT, SV, maximum velocity time integral (VTI) of the descending aorta, and common carotid fell by 25.7% (
conclusionsThe pattern of SV change induced by a sEIOT/sEEOT in nonmechanically ventilated volunteers is reflected in the common carotid artery and descending aorta. The VTI variability of the Doppler patch was less than that of the traditional, duplex Doppler.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials