ArticleScience (New York, N.Y.)2020
Cryo-EM with sub-1 Å specimen movement.
Article in Science (New York, N.Y.), 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 69 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
69 citing papers in PubMed, 138 citations in OpenAlex.
- Control of ice thickness in cryo-EM via confinement.Nature methods · 2026Article
- WebCalEM: a browser-based tool for routine and accurate pixel-size calibration in cryo-EM.Acta crystallographica. Section F, Structural biology communications · 2026Article
- Laser phase plate improves structure determination of small proteins by cryo-EM.Science (New York, N.Y.) · 2026Article
- WebCalEM: a browser-based tool for routine and accurate pixel size calibration in cryo-EM.bioRxiv : the preprint server for biology · 2026Article
- Measurement of atomic scattering factors by cryoelectron microscopy.Proceedings of the National Academy of Sciences of the United States of America · 2026Article
- Unbend, correction of local beam-induced sample motion in cryo-EM images using a 3D spline model.eLife · 2026Article
- A Surfactant Cocktail Overcomes Air-Water Interface Artifacts in Single-Particle CryoEM.bioRxiv : the preprint server for biology · 2026Article
- Structural Basis for CbioRxiv : the preprint server for biology · 2026Article
- Molecular basis of mitogen-activated protein kinase ERK2 activation by its upstream kinase MEK1.bioRxiv : the preprint server for biology · 2026Article
- Crossing scales and eras: Correlative multimodal microscopy heritage studies.Journal of microscopy · 2026Article
- MISO: microfluidic protein isolation enables single-particle cryo-EM structure determination from a single cell colony.Nature methods · 2025Article
- Cryo-electron tomography reconstructs polymer in liquid film for fab-compatible lithography.Nature communications · 2025Article
- Ultracold cryogenic TEM with liquid helium and high stability.Proceedings of the National Academy of Sciences of the United States of America · 2025Article
- Advancing Cryo-EM and Cryo-ET through Innovation in Sample Carriers: A Perspective.Analytical chemistry · 2025Review
- Extending the reach of single-particle cryoEM.Current opinion in structural biology · 2025Review
- RNA sample optimization for cryo-EM analysis.Nature protocols · 2025Review
- Comprehensive microcrystal electron diffraction sample preparation for cryo-EM.Nature protocols · 2025Review
- Reducing the effects of radiation damage in cryo-EM using liquid helium temperatures.Proceedings of the National Academy of Sciences of the United States of America · 2025Article
- Self-assembled superstructure alleviates air-water interface effect in cryo-EM.Nature communications · 2024Article
- Correction of preferred orientation-induced distortion in cryo-electron microscopy maps.Science advances · 2024Article
9 more citing papers are in PubMed but not listed here.
Corrections and comments
- Commented on by
- Commented on by
Authors and funding
3 authors at 1 institution in 2 countries.
Funding
Abstract
Most information loss in cryogenic electron microscopy (cryo-EM) stems from particle movement during imaging, which remains poorly understood. We show that this movement is caused by buckling and subsequent deformation of the suspended ice, with a threshold that depends directly on the shape of the frozen water layer set by the support foil. We describe a specimen support design that eliminates buckling and reduces electron beam-induced particle movement to less than 1 angstrom. The design allows precise foil tracking during imaging with high-speed detectors, thereby lessening demands on cryostage precision and stability. It includes a maximal density of holes, which increases throughput in automated cryo-EM without degrading data quality. Movement-free imaging allows extrapolation to a three-dimensional map of the specimen at zero electron exposure, before the onset of radiation damage.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials