Evidence map›Paper›PMID 33032338›Full record

ArticleJournal of the American Academy of Audiology2020

The Effect of Hearing Loss on Localization of Amplitude-Panned and Physical Sources.

Gregory M Ellis, Pamela E Souza

Abstract read
In one paragraph

Article in Journal of the American Academy of Audiology, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors.

Gregory M EllisDepartment of Communication Sciences and Disorders, Northwestern University, Evanston, Illinois.
Pamela E SouzaDepartment of Communication Sciences and Disorders, Northwestern University, Evanston, Illinois.

Funding

Acoustic and Perceptual Effects of WDRC AmplificationR01DC006014 · NIDCD · UNIVERSITY OF WASHINGTON · PI SOUZA, PAMELA E. · 2005 to 2020
$3.9M
NIDCD NIH HHS R01 DC006014
6 · The paper itself

Abstract

backgroundClinics are increasingly turning toward using virtual environments to demonstrate and validate hearing aid fittings in "realistic" listening situations before the patient leaves the clinic. One of the most cost-effective and straightforward ways to create such an environment is through the use of a small speaker array and amplitude panning. Amplitude panning is a signal playback method used to change the perceived location of a source by changing the level of two or more loudspeakers. The perceptual consequences (i.e., perceived source width and location) of amplitude panning have been well-documented for listeners with normal hearing but not for listeners with hearing impairment. PURPOSE: The purpose of this study was to examine the perceptual consequences of amplitude panning for listeners with hearing statuses from normal hearing through moderate sensorineural hearing losses. RESEARCH

designListeners performed a localization task. Sound sources were broadband 4 Hz amplitude-modulated white noise bursts. Thirty-nine sources (14 physical) were produced by either physical loudspeakers or via amplitude panning. Listeners completed a training block of 39 trials (one for each source) before completing three test blocks of 39 trials each. Source production method was randomized within block. STUDY SAMPLE: Twenty-seven adult listeners (mean age 52.79, standard deviation 27.36, 10 males, 17 females) with hearing ranging from within normal limits to moderate bilateral sensorineural hearing loss participated in the study. Listeners were recruited from a laboratory database of listeners that consented to being informed about available studies. DATA COLLECTION AND ANALYSIS: Listeners indicated the perceived source location via touch screen. Outcome variables were azimuth error, elevation error, and total angular error (Euclidean distance in degrees between perceived and correct location). Listeners' pure-tone averages (PTAs) were calculated and used in mixed-effects models along with source type and the interaction between source type and PTA as predictors. Subject was included as a random variable.

resultsSignificant interactions between PTA and source production method were observed for total and elevation errors. Listeners with higher PTAs (i.e., worse hearing) did not localize physical and panned sources differently whereas listeners with lower PTAs (i.e., better hearing) did. No interaction was observed for azimuth errors; however, there was a significant main effect of PTA.

conclusionAs hearing impairment becomes more severe, listeners localize physical and panned sources with similar errors. Because physical and panned sources are not localized differently by adults with hearing loss, amplitude panning could be an appropriate method for constructing virtual environments for these listeners.

Indexed as

DeafnessHearing AidsHearing LossHearing Loss, SensorineuralSound LocalizationSpeech PerceptionAdultAgedAged, 80 and overFemaleHearing Loss, BilateralHumansMaleMiddle AgedNoise

Identifiers

PMID33032338
PMCPMC8579943

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.