ArticleArtificial organs2021
Patient-specific in vitro testing for evaluating TAVR clinical performance-A complementary approach to current ISO standard testing.
Article in Artificial organs, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
9 citing papers in PubMed, 9 citations in OpenAlex.
- Manufacturing 3D aortic root models for in vitro assessment of calcific aortic valve stenosis.Annals of biomedical engineering · 2026Article
- Development of a Polymeric TAVR Device Tailored to Bicuspid Aortic Valve Patients Using In Silico Design Optimization and Evaluation.Annals of biomedical engineering · 2026Article
- AI-Powered Multimodal Modeling of Personalized Hemodynamics in Aortic Stenosis.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2025Article
- Design and Analysis of a Polymeric Left Ventricular Simulator via Computational Modelling.Biomimetics (Basel, Switzerland) · 2024Article
- Soft robotic patient-specific hydrodynamic model of aortic stenosis and ventricular remodeling.Science robotics · 2023Article
- Mild Paravalvular Leak May Pose an Increased Thrombogenic Risk in Transcatheter Aortic Valve Replacement (TAVR) Patients-Insights from Patient Specific In Vitro and In Silico Studies.Bioengineering (Basel, Switzerland) · 2023Article
- Validating In Silico and In Vitro Patient-Specific Structural and Flow Models with Transcatheter Bicuspid Aortic Valve Replacement Procedure.Cardiovascular engineering and technology · 2022Article
- Visions of TAVR Future: Development and Optimization of a Second Generation Novel Polymeric TAVR.Journal of biomechanical engineering · 2022Article
- A Robot Mimicking Heart Motions: An Ex-Vivo Test Approach for Cardiac Devices.Cardiovascular engineering and technology · 2022Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 3 institutions in 1 country.
Funding
Abstract
Following in vitro tests established for surgical prosthetic heart valves, transcatheter aortic valves (TAV) are similarly tested in idealized geometries-excluding effects that may hamper TAVR performance in situ. Testing in vitro in pulse duplicator systems that incorporated patient-specific replicas would enhance the testing veracity by bringing it closer to the clinical scenario. To that end we compare TAV hemodynamic performance tested in idealized geometries according to the ISO standard (baseline performance) to that obtained by testing the TAVs following deployment in patient-specific replicas. Balloon-expandable (n = 2) and self-expandable (n = 3) TAVs were tested in an idealized geometry in mock-circulation system (following ISO 5840-3 guidelines) and compared to the measurements in a dedicated mock-circulation system adapted for the five patient-specific replicas. Patient-specific deployments resulted in a decline in performance as compared to the baseline idealized testing, as well as a variation in performance that depended on the design features of each device that was further correlated with the radial expansion and eccentricity of the deployed TAV stent (obtained with CT-scans of the deployed valves). By excluding the deployment effects in irregular geometries, the current idealized ISO testing is limited to characterize the baseline device performance. Utilizing patient-specific anatomic contours provides performance indicators under more stringent conditions likely encountered in vivo. It has the potential to enhance testing and development complementary to the ISO standard, for improved TAV safety and effectiveness.