Validation of the Polar V800 heart rate monitor and comparison of artifact correction methods among adults with hypertension.

Burak Cilhoroz, David Giles, Amanda Zaleski, Beth Taylor, Bo Fernhall, Linda Pescatello

Open access · goldAbstract readComparative StudyValidation Study
In one paragraph

Article in PloS one, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 17 papers, 2 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
17citing papers in PubMed, 2 pooled it
2.2field-weighted citation impact, top 10% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

17 citing papers in PubMed, 2 syntheses or guidelines pooled it, 26 citations in OpenAlex.

  1. Pooled it
  2. Pooled it
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Article
  14. Observational
  15. Observational
  16. Article
  17. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 4 institutions in 2 countries.

Burak CilhorozDepartment of Kinesiology, University of Connecticut, Storrs, Connecticut, United States of America.ORCID 0000-0002-5011-2911
David GilesHealth and Social Care Research Centre, University of Derby, Derby, United Kingdom.
Amanda ZaleskiDepartment of Kinesiology, University of Connecticut, Storrs, Connecticut, United States of America.
Beth TaylorDepartment of Kinesiology, University of Connecticut, Storrs, Connecticut, United States of America.
Bo FernhallCollege of Applied Health Sciences, University of Illinois at Chicago, Chicago, Illinois, United States of America.
Linda PescatelloDepartment of Kinesiology, University of Connecticut, Storrs, Connecticut, United States of America.
Hartford Hospital · USUniversity of Connecticut · USUniversity of Derby · GBUniversity of Illinois Chicago · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Heart rate variability (HRV) measurements via ambulatory monitors have become common. We examined the validity of recording R-R intervals using the Polar V800™ compared to 12-lead electrocardiograms (ECG) among middle-aged (44.7±10.1years); overweight to obese (29.8±4.3 kg.m-2) adults (n = 25) with hypertension (132.3±12.2/ 84.3±10.2 mmHg). After resting for 5-min in the supine position, R-R intervals were simultaneously recorded using the Polar V800™ and the 12-lead ECG. Artifacts present in uncorrected (UN) R-R intervals were corrected with the Kubios HRV Premium (ver. 3.2.) automatic (AC) and threshold-based (TBC) correction, and manual correction (MC) methods. Intra-class correlation coefficients (ICC), Bland-Altman limits of agreement (LoA), and effect sizes (ES) were calculated. We detected 71 errors with the Polar V800™ for an error rate of 0.85%. The bias (LoAs), ES, and ICC between UN and ECG R-R intervals were 0.69ms (-215.80 to +214.42ms), 0.004, and 0.79, respectively. Correction of artifacts improved the agreeability between the Polar V800™ and ECG HRV measures. The biases (LoAs) between the AC, TBC, and MC and ECG R-R intervals were 3.79ms (-130.32 to +137.90ms), 1.16ms (-92.67 to +94.98ms), and 0.37ms (-41.20 to +41.94ms), respectively. The ESs of AC, TBC, and MC were 0.024, 0.008, and 0.002, and ICCs were 0.91, 0.95, and 1.00, respectively. R-R intervals measured using the Polar V800™ compared to 12-lead ECG were comparable in adults with hypertension, especially after the artifacts corrected by MC. However, TBC correction also yielded acceptable results.

Indexed as

ArtifactsHeart RateAdultAgingBody Mass IndexElectrocardiographyFemaleHumansHypertensionMaleMiddle AgedMonitoring, Physiologic

Identifiers

PMID33031480
PMCPMC7544136
OpenAlexW3092459727

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.