Sensor orientation and other factors which increase the blast overpressure reporting errors.

Anthony Misistia, Maciej Skotak, Arturo Cardenas, Eren Alay, Namas Chandra, Gary H Kamimori

Abstract read
In one paragraph

Article in PloS one, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Anthony MisistiaBlast Induced Neurotrauma Department, Walter Reed Army Institute of Research, Silver Spring, MD, United States of America.
Maciej SkotakBlast Induced Neurotrauma Department, Walter Reed Army Institute of Research, Silver Spring, MD, United States of America.ORCID 0000-0003-2584-7294
Arturo CardenasBlast Induced Neurotrauma Department, Walter Reed Army Institute of Research, Silver Spring, MD, United States of America.
Eren AlayDepartment of Biomedical Engineering, New Jersey Institute of Technology, University Heights, Newark, NJ, United States of America.
Namas ChandraDepartment of Biomedical Engineering, New Jersey Institute of Technology, University Heights, Newark, NJ, United States of America.
Gary H KamimoriBlast Induced Neurotrauma Department, Walter Reed Army Institute of Research, Silver Spring, MD, United States of America.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

This study compared the response of the wearable sensors tested against the industry-standard pressure transducers at blast overpressure (BOP) levels typically experienced in training. We systematically evaluated the effects of the sensor orientation with respect to the direction of the incident shock wave and demonstrated how the averaging methods affect the reported pressure values. The evaluated methods included averaging peak overpressure and impulse of all four sensors mounted on a helmet, taking the average of the three sensors, or isolating the incident pressure equivalent using two sensors. The experimental procedures were conducted in controlled laboratory conditions using the shock tube, and some of the findings were verified in field conditions with live fire charges during explosive breaching training. We used four different orientations (0°, 90°, 180°, and 270°) of the headform retrofitted with commonly fielded helmets (ACH, ECH, Ops-Core) with four B3 Blast Gauge sensors. We determined that averaging the peak overpressure values overestimates the actual dosage experienced by operators, which is caused by the reflected pressure contribution. This conclusion is valid despite the identified limitation of the B3 gauges that consistently underreport the peak reflected overpressure, compared to the industry-standard sensors. We also noted consistent overestimation of the impulse. These findings demonstrate that extreme caution should be exercised when interpreting occupational blast exposure results without knowing the orientation of the sensors. Pure numerical values without the geometrical, training-regime specific information such as the position of the sensors, the distance and orientation of the trainee to the source of the blast wave, and weapon system used will inevitably lead to erroneous estimation of the individual and cumulative blast overpressure (BOP) dosages. Considering that the 4 psi (~28 kPa) incident BOP is currently accepted as the threshold exposure safety value, a misinterpretation of exposure level may lead to an inaccurate estimation of BOP at the minimum standoff distance (MSD), or exclusion criteria.

Indexed as

ExplosionsPressureResearch DesignWearable Electronic DevicesHead Protective Devices

Identifiers

PMID33031423
PMCPMC7544144

What OpenQuestion holds

Textmetadata
LicenceCC0
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.