ArticleEuropean radiology2021
Noise reduction approach in pediatric abdominal CT combining deep learning and dual-energy technique.
Article in European radiology, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 26 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
26 citing papers in PubMed, 48 citations in OpenAlex.
- Low-contrast-dose liver CT using low monoenergetic images with deep learning-based denoising for assessing hepatocellular carcinoma: a randomized controlled noninferiority trial.European radiology · 2023Trial
- Performance of Commercial Deep Learning-Based Radiation Dose Optimization Software in Pediatric Radiology: A Systematic Review.Children (Basel, Switzerland) · 2026Review
- Feasibility of single-phase DECT as an alternative to triple-phase CT for imaging-defined risk factors assessment in neuroblastoma for dose reduction.European journal of radiology open · 2026Article
- Photon-Counting Detector CT Allows Abdominal Virtual Monoenergetic Imaging at Lower Kiloelectron Volt Level with Lower Noise Using Lower Radiation Dose: A Prospective Matched Study Compared to Energy-Integrating Detector CT.Journal of imaging informatics in medicine · 2026Article
- Deep-learning reconstruction for noncontrast head computed tomography: Improved image quality and potential diagnostic impact in acute ischemic stroke.Neuroradiology · 2026Article
- Hypersensitive detection of single millimeter vascular emboli from adhesive in vivo.Nature communications · 2026Article
- AI-based denoising improves image quality in HCC volume perfusion CT without affecting Milan classification.BMC medical imaging · 2026Article
- Dual-energy computed tomography in children: Technique and clinical applications.World journal of clinical pediatrics · 2025Review
- Comparison of iterative reconstruction implementations for multislice helical CT.Zeitschrift fur medizinische Physik · 2025Article
- Agreement between Routine-Dose and Lower-Dose CT with and without Deep Learning-based Denoising for Active Surveillance of Solid Small Renal Masses: A Multiobserver Study.Radiology. Imaging cancer · 2025Article
- Performance Evaluation of Image Segmentation Using Dual-Energy Spectral CT Images with Deep Learning Image Reconstruction: A Phantom Study.Tomography (Ann Arbor, Mich.) · 2025Article
- CT-Free Attenuation Correction in Paediatric Long Axial Field-of-View Positron Emission Tomography Using Synthetic CT from Emission Data.Diagnostics (Basel, Switzerland) · 2024Article
- Low-iodine-dose computed tomography coupled with an artificial intelligence-based contrast-boosting technique in children: a retrospective study on comparison with conventional-iodine-dose computed tomography.Pediatric radiology · 2024Article
- Diagnostic performance and image quality of an image-based denoising algorithm applied to radiation dose-reduced CT in diagnosing acute appendicitis.Abdominal radiology (New York) · 2024Article
- Generative Adversarial Network (Generative Artificial Intelligence) in Pediatric Radiology: A Systematic Review.Children (Basel, Switzerland) · 2023Review
- Evaluation of Image Quality and Detectability of Deep Learning Image Reconstruction (DLIR) Algorithm in Single- and Dual-energy CT.Journal of digital imaging · 2023Article
- Performance of 1-mm non-gated low-dose chest computed tomography using deep learning-based noise reduction for coronary artery calcium scoring.European radiology · 2023Article
- Significant CT dose reduction of 2-[European radiology · 2023Article
- Iterative reconstructionThe British journal of radiology · 2022Article
- Artificial Intelligence for Radiation Dose Optimization in Pediatric Radiology: A Systematic Review.Children (Basel, Switzerland) · 2022Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors at 3 institutions in 3 countries.
Funding
Abstract
objectivesTo evaluate the image quality of low iodine concentration, dual-energy CT (DECT) combined with a deep learning-based noise reduction technique for pediatric abdominal CT, compared with standard iodine concentration single-energy polychromatic CT (SECT).
methodsFrom December 2016 to May 2017, DECT with 300 mg•I/mL contrast medium was performed in 29 pediatric patients (17 boys, 12 girls; age, 2-19 years). The DECT images were reconstructed using a noise-optimized virtual monoenergetic reconstruction image (VMI) with and without a deep learning method. SECT images with 350 mg•I/mL contrast medium, performed within the last 3 months before the DECT, served as reference images. The quantitative and qualitative parameters were compared using paired t tests and Wilcoxon signed-rank tests, and the differences in radiation dose and total iodine administration were assessed.
resultsThe linearly blended DECT showed lower attenuation and higher noise than SECT. The 60-keV VMI showed an increase in attenuation and higher noise than SECT. The combined 60-keV VMI plus deep learning images showed low noise, no difference in contrast-to-noise ratios, and overall image quality or diagnostic image quality, but showed a higher signal-to-noise ratio in the liver and lower enhancement of lesions than SECT. The overall image and diagnostic quality of lesions were maintained on the combined noise reduction approach. The CT dose index volume and total iodine administration in DECT were respectively 19.6% and 14.3% lower than those in SECT.
conclusionLow iodine concentration DECT, combined with deep learning in pediatric abdominal CT, can maintain image quality while reducing the radiation dose and iodine load, compared with standard SECT. KEY POINTS: • An image noise reduction approach combining deep learning and noise-optimized virtual monoenergetic image reconstruction can maintain image quality while reducing radiation dose and iodine load. • The 60-keV virtual monoenergetic image reconstruction plus deep learning images showed low noise, no difference in contrast-to-noise ratio, and overall image quality, but showed a higher signal-to-noise ratio in the liver and a lower enhancement of lesion than single-energy polychromatic CT. • This combination could offer a 19.6% reduction in radiation dose and a 14.3% reduction in iodine load, in comparison with a control group that underwent single-energy polychromatic CT with the standard protocol.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.