ArticleSensors (Basel, Switzerland)2020
Sleep Stage Estimation from Bed Leg Ballistocardiogram Sensors.
Article in Sensors (Basel, Switzerland), 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 13 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
13 citing papers in PubMed.
- Unobtrusive Bed Monitor State of the Art.Sensors (Basel, Switzerland) · 2025Review
- What radio waves tell us about sleep!Sleep · 2025Article
- Prediction of ECG signals from ballistocardiography using deep learning for the unconstrained measurement of heartbeat intervals.Scientific reports · 2025Article
- A new objective titration procedure using Remotely Contactless Intelligent Sleep Monitoring System for the treatment of mandibular advancement device in OSAHS patient.Frontiers in neurology · 2025Article
- Enhancing sleep stage classification with ballistocardiogram signals: feature selection using attention mechanism and XGBoost.Frontiers in public health · 2025Article
- The association between salivary IL-6 and poor sleep quality assessed using Apple watches in stressed workers in Japan.Scientific reports · 2024Article
- Estimating Physical Activity and Sleep using the Combination of Movement and Heart Rate: A Systematic Review and Meta-Analysis.International journal of exercise science · 2023Review
- Non-invasive monitoring of cardiac function through Ballistocardiogram: an algorithm integrating short-time Fourier transform and ensemble empirical mode decomposition.Frontiers in physiology · 2023Article
- Associations between perioperative sleep patterns and clinical outcomes in patients with intracranial tumors: a correlation study.Frontiers in neurology · 2023Article
- Impact of Preoperative Sleep Disturbances on Postoperative Delirium in Patients with Intracranial Tumors: A Prospective, Observational, Cohort Study.Nature and science of sleep · 2023Article
- Investigating Cardiorespiratory Interaction Using Ballistocardiography and Seismocardiography-A Narrative Review.Sensors (Basel, Switzerland) · 2022Review
- Digital Optical Ballistocardiographic System for Activity, Heart Rate, and Breath Rate Determination during Sleep.Sensors (Basel, Switzerland) · 2022Article
- Estimating Sleep Stages Using a Head Acceleration Sensor.Sensors (Basel, Switzerland) · 2021Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Ballistocardiogram (BCG) is a graphical representation of the subtle oscillations in body movements caused by cardiovascular activity. Although BCGs cause less burden to the user, electrocardiograms (ECGs) are still commonly used in the clinical scene due to BCG sensors' noise sensitivity. In this paper, a robust method for sleep time BCG measurement and a mathematical model for predicting sleep stages using BCG are described. The novel BCG measurement algorithm can be described in three steps: preprocessing, creation of heartbeat signal template, and template matching for heart rate variability detection. The effectiveness of this algorithm was validated with 99 datasets from 36 subjects, with photoplethysmography (PPG) to compute ground truth heart rate variability (HRV). On average, 86.9% of the inter-beat intervals were detected and the mean error was 8.5ms. This shows that our method successfully extracted beat-to-beat intervals from BCG during sleep, making its usability comparable to those of clinical ECGs. Consequently, compared to other conventional BCG systems, even more accurate sleep heart rate monitoring with a smaller burden to the patient is available. Moreover, the accuracy of the sleep stages mathematical model, validated with 100 datasets from 25 subjects, is 80%, which is higher than conventional five-stage sleep classification algorithms (max: 69%). Although, in this paper, we applied the mathematical model to heart rate interval features from BCG, theoretically, this sleep stage prediction algorithm can also be applied to ECG-extracted heart rate intervals.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.