Evidence map›Paper›PMID 33027844›Full record

SynthesisThe Cochrane database of systematic reviews2020

Vena caval filters for the prevention of pulmonary embolism.

Tim Young, Krishna Bajee Sriram

Abstract readSystematic Review
In one paragraph

Synthesis in The Cochrane database of systematic reviews, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 14 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
14citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

14 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Article
  3. Article
  4. Article
  5. Right Ventricle Embolization of IVC Filter Fragments: An Incidental Finding.The International journal of angiology : official publication of the International College of Angiology, Inc · 2025
    Article
  6. Review
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Article
  14. Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

2 authors.

Tim YoungDepartment of Medicine, Gold Coast University Hospital, Southport, Australia.
Krishna Bajee SriramDepartment of Respiratory Medicine, Gold Coast University Hospital, Southport, Australia.

Funding

Chief Scientist Office ETM/442
6 · The paper itself

Abstract

backgroundPulmonary emboli (PE), or blood clots in the lungs,can be potentially fatal. Anticoagulation is the first line therapy to prevent PE. In some instances anticoagulation fails to prevent more emboli, or cannot be given because the person has a high risk of bleeding. Inferior vena caval filters (VCFs) are metal alloy devices that mechanically trap fragmented emboli from the deep leg veins en route to the pulmonary circulation. Retrievable filters are designed to be introduced and removed percutaneously. Although their deployment seems of theoretical benefit, their clinical efficacy and adverse event profile is unclear. This is the third update of a Cochrane Review first published in 2007.

objectivesTo assess the evidence for the effectiveness and safety of vena caval filters (VCFs) in preventing pulmonary embolism (PE). SEARCH

methodsFor this review update, the Cochrane Vascular Information Specialist (CIS) searched the Specialised Register (last searched 10 September 2019) and the Cochrane Register of Controlled Trials (CENTRAL) (2019, Issue 8) via the Cochrane Register of Studies Online. The CIS also searched MEDLINE Ovid, EMBASE Ovid, CINAHL, and AMED (1 January 2017 to 10 September 2019) and trials registries to 10 September 2019. SELECTION CRITERIA: We included randomised controlled trials (RCTs) and controlled clinical trials (CCTs) that examined the efficacy of VCFs in preventing PE. DATA COLLECTION AND ANALYSIS: For this update, studies were assessed and data extracted independently. We assessed study quality with Cochrane's 'Risk of bias' tool and used the GRADE approach to assess the overall certainty of the evidence. The outcomes of interest were PE, mortality, lower limb venous thrombosis, filter-related complications and major bleeding. MAIN

resultsWe identified four new studies for this update, bringing the total to six included studies involving 1388 participants. The six studies were clinically heterogeneous and we were unable to carry out meta-analysis. Only two studies were considered to be both applicable in current clinical settings and of good methodological quality. One was a randomised open-label trial studying the effect of a retrievable inferior vena caval filter plus anticoagulation versus anticoagulation alone on risk of recurrent pulmonary embolism (PE) in 399 participants over three months. There was no evidence of a difference in the rates of PE, death, lower extremity deep vein thrombosis (DVT), or bleeding at three and six months after the intervention (moderate-certainty evidence). A filter was inserted in 193 people, but could only be successfully retrieved from 153. Minor filter complications were noted at six months. The second clinically relevant study was a randomised open-label trial of 240 participants who had sustained multiple traumatic injuries, allocated to a filter or no filter, three days after injury, in conjunction with anticoagulation and intermittent pneumatic compression. Prophylactic anticoagulation was initiated in both groups when it was thought safe to do so. There was no evidence of a difference in symptomatic PE, death, or lower limb venous thrombosis rates (moderate-certainty evidence). The only major filter complication was that one person required surgical removal of the filter. We are unable to draw any conclusions from the remaining four included studies. One study showed an increased incidence of long-term lower extremity DVT at eight years. Three studies are no longer clinically applicable because they utilised permanent filters which are seldom used now, or they did not use routine prophylactic anticoagulation which is current standard practice. The fourth study compared two filter types and was terminated prematurely as one filter group had a higher rate of thrombosis compared to the other filter type. AUTHORS'

conclusionsTwo of the six identified studies were relevant for current clinical settings. One showed no evidence of a benefit of retrievable filters in acute PE for the outcomes of PE, death, DVT and bleeding during the initial three months in people who can receive anticoagulation (moderate-certainty evidence). The other study did not show any benefit for prophylactic filter insertion in people who sustained multiple traumatic injuries, with respect to symptomatic PE, mortality, or lower extremity venous thrombosis (moderate-certainty evidence). We can draw no firm conclusions regarding filter efficacy in the prevention of PE from the remaining four RCTs identified in this review. Further trials are needed to assess vena caval filter effectiveness and safety, and clinical differences between various filter types.

Indexed as

Vena Cava FiltersAnticoagulantsCombined Modality TherapyHumansIntermittent Pneumatic Compression DevicesMultiple TraumaPulmonary EmbolismRandomized Controlled Trials as TopicRecurrenceVena Cava, InferiorVenous ThrombosisAnticoagulants

Identifiers

PMID33027844
PMCPMC8971091

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.