ReviewDer Orthopade2020
Impingement of metal-polyethylene hip prostheses : Potential cause of high systemic titanium levels?
Review in Der Orthopade, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
4 citing papers in PubMed, 5 citations in OpenAlex.
- How In Vivo Alteration of Hip Replacement Wear Mode Can Cause a Voluminous Inflammatory Reaction and an Excessive Titanium Exposure.Journal of clinical medicine · 2025Article
- Article
- Finite Element Analysis of Femoral-Acetabular Impingement (FAI) Based on Three-Dimensional Reconstruction.Journal of healthcare engineering · 2022Article
- Semi-Automated Determination of Heavy Metals in Autopsy Tissue Using Robot-Assisted Sample Preparation and ICP-MS.Molecules (Basel, Switzerland) · 2021Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
High blood metal levels have been described in the past, primarily in metal-on-metal bearings. Other possible causes are often underestimated. This report presents the case of a 70-year-old female patient who suffered from pronounced neurological symptoms (especially fatigue and concentration problems) 13 years after implantation of a hip endoprosthesis with metal-polyethylene (ME-PE) bearing. An osteolysis in the pelvis and loosening of the acetabular component were detected. In addition, large quantities of metallic black discolored granulomas were detected in the periarticular environment during surgery. A ventral impingement with destruction of the titanium cup and the PE insert was identified as the suspected cause of this condition. The postoperative course of the blood metal levels was unexpected as titanium levels increased massively in the blood. Anamnesis, course of the disease and the surgical procedure as well as especially the course of the metal values in the blood of the patient are presented. Possible causes for the excessive occurrence of metal abrasion, the systemic distribution and potential toxic effects of titanium are explained and discussed in detail. In addition, the currently available literature on the subject is critically examined.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.