ReviewPhotoacoustics2020
Towards non-contact photoacoustic imaging [review].
Review in Photoacoustics, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 39 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
39 citing papers in PubMed, 102 citations in OpenAlex.
- Effective point spread function modeling of photoacoustic remote sensing microscopy towards resolution enhancement.Photoacoustics · 2026Article
- Fully integrated photoacoustic microscopy for multi-scale and longitudinal imaging in translational biomedical applications.Biomedical optics express · 2026Article
- Ultrathin Soft Wearable Sensor Materials and Structures: A Review of Current Trends and Prospectives.ACS applied materials & interfaces · 2025Review
- Multi-photon, label-free photoacoustic and optical imaging of NADH in brain cells.Light, science & applications · 2025Article
- Intersection of ferroptosis and nanomaterials brings benefits to breast cancer.Cell biology and toxicology · 2025Review
- Hybrid transformer-CNN network-driven optical-scanning undersampling for photoacoustic remote sensing microscopy.Photoacoustics · 2025Article
- Emerging Wearable Acoustic Sensing Technologies.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2025Review
- Non-contact electroacoustic tomography with optical interferometer for electroporation therapy monitoring.Applied physics letters · 2025Article
- Resolution Enhancement Strategies in Photoacoustic Microscopy: A Comprehensive Review.Micromachines · 2024Review
- Potential applications for photoacoustic imaging using functional nanoparticles: A comprehensive overview.Heliyon · 2024Review
- Luminescence Probes in Bio-Applications: From Principle to Practice.Biosensors · 2024Review
- Non-invasive evaluation of endometrial microvessels via in vivo intrauterine photoacoustic endoscopy.Photoacoustics · 2024Article
- Dynamic modeling of photoacoustic sensor data to classify human blood samples.Medical & biological engineering & computing · 2024Article
- Intravital photoacoustic brain stimulation with high-precision.Journal of biomedical optics · 2024Review
- Resonance frequency measurement to identify stiffness variations based on photoacoustic imaging.Biophysics and physicobiology · 2024Article
- Advances in photoacoustic imaging aided by nano contrast agents: special focus on role of lymphatic system imaging for cancer theranostics.Journal of nanobiotechnology · 2023Review
- Development status of novel spectral imaging techniques and application to traditional Chinese medicine.Journal of pharmaceutical analysis · 2023Review
- Noise insensitive volumetric fusion method for enhanced photoacoustic microscopy.Journal of biomedical optics · 2023Article
- Modeling of Rapid Pam Systems Based on Electrothermal Micromirror for High-Resolution Facial Angiography.Sensors (Basel, Switzerland) · 2023Article
- Multifunctional nanoparticle for cancer therapy.MedComm · 2023Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Photoacoustic imaging (PAI) takes advantage of both optical and ultrasound imaging properties to visualize optical absorption with high resolution and contrast. Photoacoustic microscopy (PAM) is usually categorized with all-optical microscopy techniques such as optical coherence tomography or confocal microscopes. Despite offering high sensitivity, novel imaging contrast, and high resolution, PAM is not generally an all-optical imaging method unlike the other microscopy techniques. One of the significant limitations of photoacoustic microscopes arises from their need to be in physical contact with the sample through a coupling media. This physical contact, coupling, or immersion of the sample is undesirable or impractical for many clinical and pre-clinical applications. This also limits the flexibility of photoacoustic techniques to be integrated with other all-optical imaging microscopes for providing complementary imaging contrast. To overcome these limitations, several non-contact photoacoustic signal detection approaches have been proposed. This paper presents a brief overview of current non-contact photoacoustic detection techniques with an emphasis on all-optical detection methods and their associated physical mechanisms.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.