Evidence map›Paper›PMID 33024634›Full record

ArticlePeerJ2020

Characterization of a high-resolution breath acetone meter for ketosis monitoring.

Donald J Suntrup Iii, Timothy V Ratto, Matt Ratto, James P McCarter

Registry-linked trialOpen access · goldAbstract read
In one paragraph

Article in PeerJ, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT05541484 (Ketone Monitoring in T1D), which is not on this map. Cited by 13 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
13citing papers in PubMed, 1 pooled it
1.6field-weighted citation impact, top 17% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT05541484 phase4completedstarted 2022, after this paper: background citation

Ketone Monitoring in T1D: Effect of SGLT2i During Usual Care and With Insulin Deficiency

Ran2022Enrolled21Registered outcomes3Posted comparisons1ConditionsDiabetes Mellitus, Type 1ArmsBiosense Breath Ketone Analyzer, SGLT2 inhibitor
Open the trial in the graph
3 · Its place in the literature

Who cites it

13 citing papers in PubMed, 1 synthesis or guideline pooled it, 19 citations in OpenAlex.

  1. Pooled it
  2. Trial
  3. Article
  4. Article
  5. Article
  6. Article
  7. Review
  8. Article
  9. Adherence to Low-Carbohydrate Diets in Patients with Diabetes: A Narrative Review.Diabetes, metabolic syndrome and obesity : targets and therapy · 2022
    Review
  10. Article
  11. Review
  12. Review
  13. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 1 institution in 1 country.

Donald J Suntrup IiiReadout Health, St. Louis, MO, United States of America.
Timothy V RattoReadout Health, St. Louis, MO, United States of America.
Matt RattoReadout Health, St. Louis, MO, United States of America.
James P McCarterAbbott Diabetes Care, Almeda, CA, United States of America.
Abbott (United States) · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThe ketone bodies beta-hydroxybutyrate (BHB) and acetone are endogenous products of fatty acid metabolism. Although ketone levels can be monitored by measuring either blood BHB or breath acetone, determining the precise correlation between these two measurement methods has been challenging. The purpose of this study is to characterize the performance of a novel portable breath acetone meter (PBAM) developed by Readout, Inc., to compare single versus multiple daily ketone measurements, and to compare breath acetone (BrAce) and blood BHB measurements.

methodsWe conducted a 14-day prospective observational cohort study of 21 subjects attempting to follow either a low-carbohydrate/ketogenic or a standard diet. Subjects were asked to concurrently measure both blood BHB and BrAce five times per day and report the results using an online data entry system. We evaluated the utility of multiple daily measurements by calculating the coefficient of variation (CV) for each daily group of measurements. We calculated the correlation between coincident BrAce and blood BHB measurements using linear ordinary least squares regression analysis. We assessed the ability of the BrAce measurement to accurately predict blood BHB states using receiver operating characteristic (ROC) analysis. Finally, we calculated a daily ketone exposure (DKE) using the area under the curve (AUC) of a ketone concentration versus time graph and compared the DKE of BrAce and blood BHB using linear ordinary least squares regression.

resultsBrAce and blood BHB varied throughout the day by an average of 44% and 46%, respectively. The BrAce measurement accurately predicted whether blood BHB was greater than or less than the following thresholds: 0.3 mM (AUC = 0.898), 0.5 mM (AUC = 0.854), 1.0 mM (AUC = 0.887), and 1.5 mM (AUC = 0.935). Coincident BrAce and blood BHB measurements were moderately correlated with

conclusionsThe results validated the performance of the PBAM. The BrAce/BHB correlation was similar to literature values where BrAce was measured using highly accurate lab instruments. Additionally, BrAce measurements using the PBAM can be used to predict blood BHB states. The relatively high daily variability of ketone levels indicate that single blood or breath ketone measurements are often not sufficient to assess daily ketone exposure for most users. Finally, although single coincident blood and breath ketone measurements show only a moderate correlation, possibly due to the temporal lag between BrAce and blood BHB, daily ketone exposures for blood and breath are highly correlated.

Indexed as

Breath acetoneChemical sensingKetogenic dietKetone monitoringKetonesMedical deviceMetabolism

Identifiers

PMID33024634
PMCPMC7520093
OpenAlexW3088873694

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.