Evidence map›Paper›PMID 33023183›Full record

ArticleSensors (Basel, Switzerland)2020

TRC-Based High-Precision Spot Position Detection in Inter-Satellite Laser Communication.

Qing Li, Hongyang Guo, Shaoxiong Xu, Yangjie Xu, Qiang Wang, Dong He, Zhenming Peng, Yongmei Huang

Abstract readLetter
In one paragraph

Article in Sensors (Basel, Switzerland), 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Qing LiInstitute of Optics and Electronics, Chinese Academy of Sciences, No.1 Guangdian Road, Chengdu 610209, China.ORCID 0000-0003-4364-1257
Hongyang GuoInstitute of Optics and Electronics, Chinese Academy of Sciences, No.1 Guangdian Road, Chengdu 610209, China.ORCID 0000-0002-3346-3656
Shaoxiong XuInstitute of Optics and Electronics, Chinese Academy of Sciences, No.1 Guangdian Road, Chengdu 610209, China.
Yangjie XuInstitute of Optics and Electronics, Chinese Academy of Sciences, No.1 Guangdian Road, Chengdu 610209, China.
Qiang WangInstitute of Optics and Electronics, Chinese Academy of Sciences, No.1 Guangdian Road, Chengdu 610209, China.
Dong HeInstitute of Optics and Electronics, Chinese Academy of Sciences, No.1 Guangdian Road, Chengdu 610209, China.
Zhenming PengSchool of Information and Communication Engineering, University of Electronic Science and Technology of China, No.2006 Xiyuan Ave, West Hi-Tech Zone, Chengdu 611731, China.ORCID 0000-0002-4148-3331
Yongmei HuangInstitute of Optics and Electronics, Chinese Academy of Sciences, No.1 Guangdian Road, Chengdu 610209, China.

Funding

National Key R&D Program of China 2017YFB1103002National Natural Science Foundation of China (NSFC) 61775030, 61571096Sichuan Science and Technology Program 2019YJ0167
6 · The paper itself

Abstract

Inter-satellite laser communication (Is-OWC) is one of the main space optical communication technologies currently studied in various countries. In recent years, a kind of Is-OWC communication terminal without independent beacon light has appeared. Such terminals do not have a separate beacon laser with a large divergence angle, but use a narrower communication beam to complete space capture and tracking. Therefore, the energy of the light beam divided by the acquisition, tracking, and aiming (ATP) system is greatly reduced. How to perform high-precision spot position detection under extremely low signal-to-noise ratio (SNR) is a problem that must be faced. Aiming to resolve this problem, this article proposes to use a cosine signal to modulate the intensity of the signal light, so as to convert the problem of detecting a weak light signal into the problem of detecting a line spectrum signal. The authors used the time reversal convolution (TRC) algorithm with a window function to suppress noise and enhance the spectrum line, so as to accurately detect the amplitudes of the weak photocurrents. Finally, by calculating the ratio of the photocurrent amplitude values, the precise spot position is obtained. In the experiment, when the output SNR of the four-quadrant detector (QD) is as low as -17.86 dB, the proposed method can still detect the spot position and the absolute error is limited within 0.0238 mrad.

Indexed as

four-quadrant detectorinter-satellite laser communication systemtime reversal convolutionweak light-spot position detection

Identifiers

PMID33023183
PMCPMC7582649

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.