ReviewProgress in retinal and eye research2021
Fundus-controlled perimetry (microperimetry): Application as outcome measure in clinical trials.
Review in Progress in retinal and eye research, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT07582042 (Integration of Lesion-tailored, Fundus-controlled Perimetry Into Routine Clinical Care for Patients With Geographic Atrophy), which is not on this map. Cited by 98 papers, 3 of them syntheses that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Integration of Lesion-tailored, Fundus-controlled Perimetry Into Routine Clinical Care for Patients With Geographic Atrophy (GA) Receiving Pegcetacoplan Treatment in Accordance With the Approved Label.
Who cites it
98 citing papers in PubMed, 3 syntheses or guidelines pooled it, 138 citations in OpenAlex.
- Visual field defects in dementia: A scoping review.Ophthalmic & physiological optics : the journal of the British College of Ophthalmic Opticians (Optometrists) · 2025Pooled it
- Retinal sensitivity changes in early/intermediate AMD: a systematic review and meta-analysis of visual field testing under mesopic and scotopic lighting.Eye (London, England) · 2024Pooled it
- Should clinical automated perimetry be considered for routine functional assessment of early/intermediate age-related macular degeneration (AMD)? A systematic review of current literature.Ophthalmic & physiological optics : the journal of the British College of Ophthalmic Opticians (Optometrists) · 2022Pooled it
- Mesopic microperimetry in Stargardt disease: Application and reliability.Acta ophthalmologica · 2026Trial
- Recovery of cone-mediated vision in Lebercilin associated retinal ciliopathy after gene therapy: One-year results of a phase I/II trial.Molecular therapy : the journal of the American Society of Gene Therapy · 2025Trial
- Randomised Clinical Trial to Evaluate the Efficacy of Acetazolamide for the Treatment of Cystoid Fluid Collections in X-Linked Retinoschisis: The AXIS Trial.Clinical & experimental ophthalmologyTrial
- Exploring fundus-controlled mesopic and scotopic perimetry in inherited retinal disease.Acta ophthalmologica · 2026Article
- Clinical Surrogate Endpoints in Malattia Leventinese/Doyne Honeycomb Retinal Dystrophy: Findings From a Two-Year Natural History Study.Investigative ophthalmology & visual science · 2026Article
- Natural History of Macular Sensitivity in Best Vitelliform Macular Dystrophy: Microperimetry-Derived Outcome Measures in Preparation For Clinical Trials.Investigative ophthalmology & visual science · 2026Article
- How "Micro" Is Microperimetry? Characterizing the Effect of Fundus Tracking on the Psychometric Function.Investigative ophthalmology & visual science · 2026Article
- Impact of Subretinal Drusenoid Deposits on Ellipsoid Zone-Related Thickness Metrics.Investigative ophthalmology & visual science · 2026Article
- Multimodal structure-function mapping of retinal sensitivity loss in pachychoroid spectrum diseases.BMC ophthalmology · 2026Article
- Longitudinal spatial correlation of retinal sensitivity and structural changes in macular telangiectasia type 2.International journal of retina and vitreous · 2026Article
- Power and clinical utility of mesopic microperimetry analysis strategies in age-related macular degeneration.Acta ophthalmologica · 2026Article
- Choroidal vascular hyperpermeability patterns in central serous chorioretinopathy correlate with microperimetry: CERTAIN study report 4.Acta ophthalmologica · 2026Article
- LAYER-SPECIFIC MICROVASCULAR CHANGES IN IDIOPATHIC EPIRETINAL MEMBRANE: Implications for Visual Function.Retina (Philadelphia, Pa.) · 2026Article
- Geographic Atrophy Structure-Function Relationships Based on Loss of OCT Outer Retinal Bands and Fundus Autofluorescence.Ophthalmology science · 2026Article
- Feasibility of Electroencephalography-Based Detection of Single-Flash Microperimetry Stimuli: A Proof-of-Concept Study.medRxiv : the preprint server for health sciences · 2026Article
- Perimetry of the Central Visual Field Using a Head-Mounted Open-Source Perimeter in Patients with Inherited Retinal Diseases.Vision (Basel, Switzerland) · 2026Article
- Visual Acuity Provides a More Meaningful Measure of Vision-Related Functioning Than Mesopic Microperimetry in Age-Related Macular Degeneration Patients: A Cross-Sectional Study.Translational vision science & technology · 2026Article
38 more citing papers are in PubMed but not listed here.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
9 authors at 6 institutions in 4 countries.
Funding
Abstract
Fundus-controlled perimetry (FCP, also called 'microperimetry') allows for spatially-resolved mapping of visual sensitivity and measurement of fixation stability, both in clinical practice as well as research. The accurate spatial characterization of visual function enabled by FCP can provide insightful information about disease severity and progression not reflected by best-corrected visual acuity in a large range of disorders. This is especially important for monitoring of retinal diseases that initially spare the central retina in earlier disease stages. Improved intra- and inter-session retest-variability through fundus-tracking and precise point-wise follow-up examinations even in patients with unstable fixation represent key advantages of these technique. The design of disease-specific test patterns and protocols reduces the burden of extensive and time-consuming FCP testing, permitting a more meaningful and focused application. Recent developments also allow for photoreceptor-specific testing through implementation of dark-adapted chromatic and photopic testing. A detailed understanding of the variety of available devices and test settings is a key prerequisite for the design and optimization of FCP protocols in future natural history studies and clinical trials. Accordingly, this review describes the theoretical and technical background of FCP, its prior application in clinical and research settings, data that qualify the application of FCP as an outcome measure in clinical trials as well as ongoing and future developments.