Evidence map›Paper›PMID 33019692›Full record

ArticlePolymers2020

Effect of Carbon Fillers on the Wear Resistance of PA6 Thermoplastic Composites.

Jerzy Myalski, Marcin Godzierz, Piotr Olesik

Open access · goldAbstract read
In one paragraph

Article in Polymers, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.

0numbers the graph read from it
0cells of the map it votes in
11citing papers in PubMed
2.7field-weighted citation impact, top 10% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

11 citing papers in PubMed, 36 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Review
  6. Article
  7. Article
  8. Review
  9. Article
  10. Review
  11. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 1 institution in 1 country.

Jerzy MyalskiSilesian University of Technology, Faculty of Materials Engineering, Krasińskiego 8, 40-019 Katowice, Poland.
Marcin GodzierzSilesian University of Technology, Faculty of Materials Engineering, Krasińskiego 8, 40-019 Katowice, Poland.
Piotr OlesikSilesian University of Technology, Faculty of Materials Engineering, Krasińskiego 8, 40-019 Katowice, Poland.
Silesian University of Technology · PL

Funding

Politechnika Śląska 11/030/BKM20/1008
6 · The paper itself

Abstract

In this study, the influence of different carbon fillers on the tribological and manufacturing properties of the thermoplastic polyamide PA6 is presented. The following materials were used as carbon additives: glassy carbon (GC), carbon obtained from the pyrolysis of polymer wastes (BC), and graphene oxide (GO). Fillers were introduced into the PA6 matrix by mechanical stirring in alcohol to settle carbon particles onto the granule surface. Samples were made by injection molding from the produced granules. The microstructure, hardness, and melt flow index (MFI) of the prepared materials were determined. Also, the degree of crystallinity of the samples was examined by Differential Scanning Calorimetry (DSC) and X-ray Diffraction (XRD). The melting point (Tm) was examined using DSC, the results from which allowed the correct heat treatment of PA6 to increase the crystallinity of the obtained material to be selected. The dry sliding tribological behavior of the composites was evaluated via pin-on-block tests against cast iron counterparts. The tests were performed at room temperature, with a sliding speed 0.1 m/s, a sliding distance of 250 m, and a normal force of 40 N. The obtained results revealed that the introduction of GO into the PA6 matrix provides favorable wear behavior, such as the formation of debris that acts as rollers that give a decrease in wear and a lower coefficient of friction. The coefficient of friction in samples with graphene oxide was nearly two times lower than with other samples. However, the ease of manufacture of this material was drastically reduced compared to GC or BC fillers. Microstructural investigations of wear tracks revealed poor adhesion between the polymer matrix and micrograins of carbon fillers (GC and BC), and therefore their influence on tribological properties was less compared to graphene oxide.

Indexed as

biocarbonglassy carbongraphene oxide (GO), polyamidewear

Identifiers

PMID33019692
PMCPMC7601268
OpenAlexW3089490706

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.