Incorporating a Ferrous Polymer Target into Elastomeric Liners for Socket Fit Sensing in Prosthesis Users.

Ryan V Carter, Brian G Larsen, Jake B McLean, Joseph L Garbini, Joan E Sanders

Open access · goldAbstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
0.3field-weighted citation impact, top 48% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 6 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Testing an adjustable prosthetic socket in a simulated military environment.Journal of rehabilitation and assistive technologies engineering
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 1 institution in 1 country.

Ryan V CarterDepartments of Bioengineering and Mechanical Engineering, University of Washington, 3720 15th Ave NE, Box 355061, Seattle, WA 98195-5061, USA.
Brian G LarsenDepartments of Bioengineering and Mechanical Engineering, University of Washington, 3720 15th Ave NE, Box 355061, Seattle, WA 98195-5061, USA.ORCID 0000-0003-1902-2480
Jake B McLeanDepartments of Bioengineering and Mechanical Engineering, University of Washington, 3720 15th Ave NE, Box 355061, Seattle, WA 98195-5061, USA.
Joseph L GarbiniDepartments of Bioengineering and Mechanical Engineering, University of Washington, 3720 15th Ave NE, Box 355061, Seattle, WA 98195-5061, USA.
Joan E SandersDepartments of Bioengineering and Mechanical Engineering, University of Washington, 3720 15th Ave NE, Box 355061, Seattle, WA 98195-5061, USA.ORCID 0000-0002-8850-243X
University of Washington · US

Funding

U.S. Army Medical Research Acquisition Activity W81XWH-16-C-0200
6 · The paper itself

Abstract

Liner-to-socket distance measurement using inductive sensing may be an effective means to continuously monitor socket fit in people using trans-tibial prostheses. A practical limitation, however, is a means to incorporate a thin uniform-thickness layer of conductive or magnetically permeable target material into the wide range of prosthetic liner products that people with limb amputation commonly use. In this paper, a method is presented whereby a 0.50-mm thickness ferrous polymer made from a SEEPS polymer and iron powder that is formed adjacent to a 0.25-mm thick non-ferrous layer of SEEPS polymer is assembled between two sheets of elastic fabric material. Bench testing showed that the fabrication procedure achieved a root-mean-square error in the thickness of this construct of 58 μm, helping to create a consistent calibration result over the entire surface. The original fabric backing of an off-the-shelf prosthetic liner was removed and replaced with the developed construct. When worn in the shoe of an able-bodied participant for 7.5 h per day for 28 days, the sensor well maintained the shape of its calibration curve at the start of wear, but a distance offset (shifting of the

Indexed as

Artificial LimbsFerrous CompoundsPolymersProsthesis DesignAmputation StumpsAmputation, SurgicalHumansFerrous CompoundsPolymersamputeedistance sensinginductive sensorinterface mechanicsprostheticsresidual limbsocket fittrans-tibialvolume management

Identifiers

PMID33019604
PMCPMC7582797
OpenAlexW3089993653

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.