Evidence map›Paper›PMID 33019373›Full record

ArticleAnnual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference2020

RF heating of deep brain stimulation implants during MRI in 1.2 T vertical scanners versus 1.5 T horizontal systems: A simulation study with realistic lead configurations.

Ehsan Kazemivalipour, Jasmine Vu, Stella Lin, Bhumi Bhusal, Bach Thanh Nguyen, John Kirsch, Behzad Elahi, Joshua Rosenow, Ergin Atalar, Laleh Golestanirad

Open access · greenAbstract read
In one paragraph

Article in Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
1.1field-weighted citation impact, top 18% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed, 13 citations in OpenAlex.

  1. Article
  2. Low-field MRI's Spark on Implant Safety: A Closer Look at Radiofrequency Heating.Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference · 2023
    Article
  3. Article
  4. Safety of MRI in patients with retained cardiac leads.Magnetic resonance in medicine · 2022
    Article
  5. Intraoperative MR Imaging during Glioma Resection.Magnetic resonance in medical sciences : MRMS : an official journal of Japan Society of Magnetic Resonance in Medicine · 2022
    Review
  6. Article
  7. Article
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors at 4 institutions in 2 countries.

Ehsan Kazemivalipour
Jasmine Vu
Stella Lin
Bhumi Bhusal
Bach Thanh Nguyen
John Kirsch
Behzad Elahi
Joshua Rosenow
Ergin Atalar
Laleh Golestanirad
Northwestern University · USBilkent University · TRMassachusetts General Hospital · USNeurological Surgery · US

Funding

Patient-adjustable MRI technology for high-resolution imaging of deep brain stimulationR00EB021320 · NIBIB · NORTHWESTERN UNIVERSITY AT CHICAGO · PI GOLESTANI RAD, LALEH · 2018 to 2020
$733k
Safety assessment of magnetic resonance imaging in patients with retained cardiac leadsR03EB025344 · NIBIB · NORTHWESTERN UNIVERSITY AT CHICAGO · PI GOLESTANI RAD, LALEH · 2018 to 2019
$156k
NIBIB NIH HHS R00 EB021320NIBIB NIH HHS R03 EB025344
6 · The paper itself

Abstract

Patients with deep brain stimulation (DBS) implants are often denied access to magnetic resonance imaging (MRI) due to safety concerns associated with RF heating of implants. Although MR-conditional DBS devices are available, complying with manufacturer guidelines has proved to be difficult as pulse sequences that optimally visualize DBS target structures tend to have much higher specific absorption rate (SAR) of radiofrequency energy than current guidelines allow. The MR-labeling of DBS devices, as well as the majority of studies on RF heating of conductive implants have been limited to horizontal close-bore MRI scanners. Vertical MRI scanners, originally introduced as open low-field MRI systems, are now available at 1.2 T field strength, capable of high-resolution structural and functional imaging. No literature exists on DBS SAR in this class of scanners which have a 90° rotated transmit coil and thus, generate a fundamentally different electric and magnetic field distributions. Here we present a simulation study of RF heating in a cohort of forty patient-derived DBS lead models during MRI in a commercially available vertical openbore MRI system (1.2 T OASIS, Hitachi) and a standard horizontal 1.5 T birdcage coil. Simulations were performed at two major imaging landmarks representing head and chest imaging. We calculated the maximum of 0.1g-averaged SAR (0.1g-SAR

Indexed as

Deep Brain StimulationHeatingHumansMagnetic Resonance ImagingProstheses and ImplantsRadio Waves

Identifiers

PMID33019373
PMCPMC10882580
OpenAlexW3082733787

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.