Evidence map›Paper›PMID 33017086›Full record

ArticleOrthopaedic surgery2020

Prediction of the Size of the Fragment in Comminuted Coronoid Fracture Using the Contralateral Side: An Analysis of Similarity of Bilateral Ulnar Coronoid Morphology.

Hai-Long Zhang, Kun-Jhih Lin, Yi Lu

Abstract read
In one paragraph

Article in Orthopaedic surgery, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Article
  2. Article
  3. Review
  4. Reconstruction of coronoid process of the ulna: a literature review.The Journal of international medical research · 2021
    Review
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Hai-Long ZhangDepartment of Sports Medicine, Beijing Jishuitan Hospital, Beijing, China.
Kun-Jhih LinDepartment of Electrical Engineering & Translation Technology Center for Medical Device, Chung Yuan Christian University, Taoyuan, China.
Yi LuDepartment of Sports Medicine, Beijing Jishuitan Hospital, Beijing, China.ORCID https://orcid.org/0000-0002-2142-887X

Funding

National Natural Science Foundation of China 81672137
6 · The paper itself

Abstract

objectiveTo evaluate the morphological similarity of bilateral coronoid process.

methodsA total of 128 sets of computed tomography images of bilateral coronoid process from patients between January 2015 and December 2016 were acquired for three-dimensional reconstruction to generate a coronoid process model. The patients were aged between 31.4 ± 9.3 years. The upper 40% of the coronoid process was trimmed as targeted fragment for morphological analysis. The height, length, width as well as the radius of the medial and lateral facet of the targeted fragment were compared in terms of laterality, age, and gender. To evaluate the similarity of the articular surface of the coronoid process, a local coordinate was created and coordinate transformation algorithm was developed to realign the bilateral coronoid process for the following matching. Then Delaunay triangulation was introduced for calculation of the area of the articular surface. After matching of articular surface of the upper 40% of bilateral coronoid process, the overlapping area of the articular surface was quantified to assess the similarity in morphology and compared in regard to age and gender.

resultsIn this study, the height of the target fragment was 12.40 ± 2.74 mm, which was 12.62 ± 2.06 mm for male patients and 12.13 ± 3.76 mm for female patients (t = 0.94, P = 0.35). The height of the target fragment was 12.79 ± 1.76 mm for patients >40 years and 13.23 ± 3.16 mm for patients <40 years (t = 1.11, P = 0.27). The height of the target fragment of left and right coronoid process was 12.26 ± 3.40 mm and 12.74 ± 2.79 mm (t = 1.15, P = 0.25). The length of the target fragment was 23.81 ± 2.67 mm, which was 23.86 ± 2.11 mm for male patients and 23.76 ± 2.85 mm for female patients (t = 0.23, P = 0.82). The length of the target fragment was 22.92 ± 1.96 mm for patients >40 years and 23.23 ± 2.14 mm for patients <40 years (t = 0.76, P = 0.45). The length of the target fragment of left and right coronoid process was 22.52 ± 2.89 mm and 21.66 ± 3.01 mm, respectively (t = 1.00, P = 0.32). The width of the target fragment was 23.12 ± 1.92 mm on average, which was 23.06 ± 1.54 mm for male patients and 23.19 ± 2.82 mm for female patients (t = 0.33, P = 0.74). The width of the target fragment was 24.82 ± 2.23 mm for patients >40 years and 23.46 ± 3.38 mm for patients <40 years (t = 1.56, P = 0.12). The width of target fragment of left and right coronoid process was 24.42 ± 2.22 mm and 24.47 ± 2.69 mm, respectively (t = 1.31, P = 0.19). The radius of medial facet was 6.44 ± 1.01 mm, which was 6.41 ± 1.39 mm for male patients and 6.47 ± 0.95 mm for female patients (t = 0.28, P = 0.78). The radius of medial facet was 6.82 ± 1.28 mm for patients >40 years and 6.46 ± 0.94 mm for patients <40 years (t = 1.31, P = 0.19). The radius of medial facet of left and right coronoid process was 6.43 ± 1.24 mm and 6.64 ± 1.34 mm (t = 1.60, P = 0.11). The radius of lateral facet was 11.84 ± 3.71 mm, which was 11.61 ± 4.24 mm for male patients and 12.11 ± 3.09 mm for female patients (t = 0.74, P = 0.46). The radius of medial facet was 11.82 ± 3.28 mm for patients >40 years and 12.46 ± 3.94 mm for patients <40 years (t = 1.02, P = 0.31). The radius of lateral facet of left and right coronoid process was 11.97 ± 5.31 mm and 10.29 ± 3.29 mm, respectively (t = 1.70, P = 0.09). The covering percentage of the articular surface of the upper 40% of bilateral coronoid process was 87% ± 12% with the covering percentage as 85.3% ± 14.2% for male patients and 90.0% ± 11.2% for female patients (t = 0.75, P = 0.41). The covering percentage was 88.2% ± 11.7% for patients >40 years and it was 87.4% ± 13.2% for patients <40 years (t = 0.98, P = 0.33).

conclusionsThe present study suggested that bilateral coronoid process shares high similarity in terms of 3D structure and articular surface morphology, which suggested that the osseous architecture of the coronoid process with comminuted fracture could be predicted by the morphological information of the contralateral side.

Indexed as

Elbow InjuriesImaging, Three-DimensionalAdultElbow JointFemaleFractures, ComminutedHumansMaleTomography, X-Ray ComputedUlnaUlna FracturesYoung AdultBilateralComparisonCoronoid processMorphology

Identifiers

PMID33017086
PMCPMC7670165

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.