Evidence map›Paper›PMID 33014585›Full record

ArticleBiomedical optics express2020

Multi-camera infrared thermography for infant respiration monitoring.

Ilde Lorato, Sander Stuijk, Mohammed Meftah, Deedee Kommers, Peter Andriessen, Carola van Pul, Gerard de Haan

Abstract read
In one paragraph

Article in Biomedical optics express, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 14 papers, 2 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
14citing papers in PubMed, 2 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

14 citing papers in PubMed, 2 syntheses or guidelines pooled it.

  1. Pooled it
  2. Pooled it
  3. Trial
  4. Article
  5. Article
  6. Article
  7. Review
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Article
  14. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Ilde LoratoDepartment of Electrical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands.ORCID https://orcid.org/0000-0002-1479-2446
Sander StuijkDepartment of Electrical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands.
Mohammed MeftahDepartment of Family Care Solutions, Philips Research, Eindhoven, The Netherlands.
Deedee KommersDepartment of Neonatology, Maxima Medical Centre, Veldhoven, The Netherlands.
Peter AndriessenDepartment of Neonatology, Maxima Medical Centre, Veldhoven, The Netherlands.
Carola van PulDepartment of Applied Physics, Eindhoven University of Technology, Eindhoven, The Netherlands.
Gerard de HaanDepartment of Electrical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Respiration is monitored in neonatal wards using chest impedance (CI), which is obtrusive and can cause skin damage to the infants. Therefore, unobtrusive solutions based on infrared thermography are being investigated. This work proposes an algorithm to merge multiple thermal camera views and automatically detect the pixels containing respiration motion or flow using three features. The method was tested on 152 minutes of recordings acquired on seven infants. We performed a comparison with the CI respiration rate yielding a mean absolute error equal to 2.07 breaths/min. Merging the three features resulted in reducing the dependency on the window size typical of spectrum-based features.

Identifiers

PMID33014585
PMCPMC7510882

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.