Evidence map›Paper›PMID 33013479›Full record

ArticleFrontiers in physiology2020

Development and Clinical Application of a Novel Non-contact Early Airflow Limitation Screening System Using an Infrared Time-of-Flight Depth Image Sensor.

Hiroki Takamoto, Hiroki Nishine, Shohei Sato, Guanghao Sun, Sadao Watanabe, Kim Seokjin, Masahito Asai, Masamichi Mineshita, Takemi Matsui

Open access · goldAbstract read
In one paragraph

Article in Frontiers in physiology, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed, 1 pooled it
0.6field-weighted citation impact, top 26% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 1 synthesis or guideline pooled it, 12 citations in OpenAlex.

  1. Pooled it
  2. Article
  3. Article
  4. Article
  5. Review
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 4 institutions in 1 country.

Hiroki TakamotoGraduate School of Systems Design, Tokyo Metropolitan University, Tokyo, Japan.
Hiroki NishineDepartment of Respiratory Medicine, St. Marianna University School of Medicine, Kanagawa, Japan.
Shohei SatoJapan Research Institute, Huawei Technologies Japan KK, Kanagawa, Japan.
Guanghao SunGraduate School of Informatics and Engineering, The University of Electro-Communications, Tokyo, Japan.
Sadao WatanabeVital Laboratories, Pvt., Ltd., Tokyo, Japan.
Kim SeokjinGraduate School of Systems Design, Tokyo Metropolitan University, Tokyo, Japan.
Masahito AsaiGraduate School of Systems Design, Tokyo Metropolitan University, Tokyo, Japan.
Masamichi MineshitaDepartment of Respiratory Medicine, St. Marianna University School of Medicine, Kanagawa, Japan.
Takemi MatsuiGraduate School of Systems Design, Tokyo Metropolitan University, Tokyo, Japan.
Tokyo Metropolitan University · JPSt. Marianna University School of Medicine · JPJapan Research Institute · JPUniversity of Electro-Communications · JP

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Obstructive pulmonary diseases, such as diffuse panbronchiolitis (DPB), asthma, chronic obstructive pulmonary disease (COPD), and asthma COPD overlap syndrome (ACOS) trigger a severe reaction at some situations. Detecting early airflow limitation caused by diseases above is critical to stop the progression. Thus, there is a need for tools to enable self-screening of early airflow limitation at home. Here, we developed a novel non-contact early airflow limitation screening system (EAFL-SS) that does not require calibration to the individual by a spirometer. The system is based on an infrared time-of-flight (ToF) depth image sensor, which is integrated into several smartphones for photography focusing or augmented reality. The EAFL-SS comprised an 850 nm infrared ToF depth image sensor (224 × 171 pixels) and custom-built data processing algorithms to visualize anterior-thorax three-dimensional motions in real-time. Multiple linear regression analysis was used to determine the amount of air compulsorily exhaled after maximal inspiration (referred to as the forced vital capacity, FVC

Indexed as

asthmacalibration freeCOPDearly airflow limitation screening systemFEV1home-usenon-contactToF depth image sensor

Identifiers

PMID33013479
PMCPMC7516262
OpenAlexW3086241038

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.