Evidence map›Paper›PMID 33011903›Full record

ArticleThe international journal of cardiovascular imaging2021

Normal reference values for mechanical mitral prosthetic valve inner diameters and areas assessed by two-dimensional and real-time three-dimensional transesophageal echocardiography.

Macit Kalçık, Mehmet Özkan, Sabahattin Gündüz, Mustafa Ozan Gürsoy, Mahmut Yesin, Emrah Bayam, Ahmet Güner, Semih Kalkan, Süleyman Karakoyun, Halil İbrahim Tanboğa

Open access · greenAbstract readComparative Study
PubMed Publisher
In one paragraph

Article in The international journal of cardiovascular imaging, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.1field-weighted citation impact, top 46% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 2 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors at 7 institutions in 1 country.

Macit KalçıkFaculty of Medicine, Department of Cardiology, Hitit University, Buharaevler Mah. Buhara 25. Sok. No:1 /A Daire:22, Çorum, Turkey. macitkalcik@yahoo.com.ORCID http://orcid.org/0000-0002-2444-7523
Mehmet ÖzkanDepartment of Cardiology, Koşuyolu Kartal Heart Training and Research Hospital, Istanbul, Turkey.
Sabahattin GündüzDepartment of Cardiology, Koşuyolu Kartal Heart Training and Research Hospital, Istanbul, Turkey.
Mustafa Ozan GürsoyDepartment of Cardiology, Izmir Katip Çelebi University, Atatürk Training and Research Hospital, Izmir, Turkey.
Mahmut YesinFaculty of Medicine, Department of Cardiology, Kars Kafkas University, Kars, Turkey.
Emrah BayamDepartment of Cardiology, Koşuyolu Kartal Heart Training and Research Hospital, Istanbul, Turkey.
Ahmet GünerDepartment of Cardiology, Mehmet Akif Ersoy Thoracic and Cardiovascular Surgery Training and Research Hospital, Istanbul, Turkey.
Semih KalkanDepartment of Cardiology, Koşuyolu Kartal Heart Training and Research Hospital, Istanbul, Turkey.
Süleyman KarakoyunFaculty of Medicine, Department of Cardiology, Kars Kafkas University, Kars, Turkey.
Halil İbrahim TanboğaFaculty of Medicine, Department of Cardiology, Nisantasi University, Istanbul, Turkey.
Kartal Koşuyolu High Specialization Training and Research Hospital · TRKafkas University · TRArdahan University · TRBurdur Mehmet Akif Ersoy Üniversitesi · TRHitit Üniversitesi · TRİstanbul Nişantaşı Üniversitesi · TRIzmir Kâtip Çelebi University · TR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

It was previously observed that two dimensional (2D) Doppler derived and real-time three-dimensional (RT-3D) directly measured valve areas were smaller than reported manufacturer sizes. It may be helpful to obtain the ranges of inner diameters (IDs) and the geometric orifice area (GOA) during evaluation of prosthetic mitral valves. In this study, we aimed to provide reference dimensional parameters of bileflet mitral mechanical prosthetic valves. Patients with recent mitral valve replacement were examined by 2D and RT-3D transesophageal echocardiography (TEE) in the early postoperative period when the presence of pannus overgrowth was unlikely. Measurements of 2D IDs, 3D hinge to hinge (HHD) and edge to edge diameters (EED) and 3D GOA were obtained and compared with reported manufacturer sizes and areas. This study enrolled 126 patients with mitral prosthetic valves (38 ATS, 42 Carbomedics, 46 St. Jude Medical, all bileaflet). The measured 2D and 3D IDs and GOA were significantly smaller than reported manufacturer sizes in the majority of the valve sizes. This RT-3D TEE-guided study provides ranges of reference values for directly measured IDs and GOA of the three most commonly used mechanical mitral prosthetic valve types for the first time in a relatively large series.

Indexed as

Heart Valve ProsthesisAdultEchocardiography, Three-DimensionalEchocardiography, TransesophagealFemaleHeart Valve DiseasesHeart Valve Prosthesis ImplantationHemodynamicsHumansMaleMiddle AgedMitral ValvePredictive Value of TestsProsthesis DesignReference StandardsTreatment OutcomeEchocardiographyInner diameterOrifice areaProsthetic valveTransesophageal echocardiography

Identifiers

PMID33011903
OpenAlexW3089604471

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.