Technical Note: On the spatial correlation between robust CT-ventilation methods and SPECT ventilation.

Edward Castillo, Richard Castillo, Yevgeniy Vinogradskiy, Girish Nair, Inga Grills, Thomas Guerrero, Craig Stevens

Abstract read
In one paragraph

Article in Medical physics, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Article
  3. Article
  4. Review
  5. Article
  6. Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Edward CastilloDepartment of Radiation Oncology, Beaumont Health Systems, Royal Oak, MI, USA.
Richard CastilloDepartment of Radiation Oncology, Emory University, Atlanta, GA, USA.
Yevgeniy VinogradskiyDepartment of Radiation Oncology, University of Colorado, Denver, CO, USA.
Girish NairDepartment of Internal Medicine, Beaumont Health Systems, Royal Oak, MI, USA.
Inga GrillsDepartment of Radiation Oncology, Beaumont Health Systems, Royal Oak, MI, USA.
Thomas GuerreroDepartment of Radiation Oncology, Beaumont Health Systems, Royal Oak, MI, USA.
Craig StevensDepartment of Radiation Oncology, Beaumont Health Systems, Royal Oak, MI, USA.

Funding

Development of a Novel Lung Function Imaging Modality for comprehensive management of lung cancerR01CA236857 · NCI · UNIVERSITY OF COLORADO DENVER · PI CASTILLO, EDWARD, CASTILLO, RICHARD · 2020 to 2025
$2.4M
HHS | NIH | National Cancer Institute (NCI) R01CA236857NCI NIH HHS R01 CA236857
6 · The paper itself

Abstract

purposeThe computed tomography (CT)-derived ventilation imaging methodology employs deformable image registration (DIR) to recover respiratory motion-induced volume changes from an inhale/exhale CT image pair, as a surrogate for ventilation. The Integrated Jacobian Formulation (IJF) and Mass Conserving Volume Change (MCVC) numerical methods for volume change estimation represent two classes of ventilation methods, namely transformation based and intensity (Hounsfield Unit) based, respectively. Both the IJF and MCVC methods utilize subregional volume change measurements that satisfy a specified uncertainty tolerance. In previous publications, the ventilation images resulting from this numerical strategy demonstrated robustness to DIR variations. However, the reduced measurement uncertainty comes at the expense of measurement resolution. The purpose of this study was to examine the spatial correlation between robust CT-ventilation images and single photon emission CT-ventilation (SPECT-V).

methodsPreviously described implementations of IJF and MCVC require the solution of a large scale, constrained linear least squares problem defined by a series of robust subregional volume change measurements. We introduce a simpler parameterized implementation that reduces the number of unknowns while increasing the number of data points in the resulting least squares problem. A parameter sweep of the measurement uncertainty tolerance,

resultsThe median correlations between MCVC and SPECT-V ranged from 0.20 to 0.48 across the parameter sweep, while the median correlations for IJF and SPECT-V ranged between 0.79 and 0.82. For the optimal IJF tolerance

conclusionThe reported correlations indicate that robust methods generate ventilation images that are spatially consistent with SPECT-V, with the transformation-based IJF method yielding higher correlations than those previously reported in the literature. For both methods, overall correlations were found to marginally vary for

Indexed as

Carcinoma, Non-Small-Cell LungLung NeoplasmsFour-Dimensional Computed TomographyHumansImage Processing, Computer-AssistedPulmonary VentilationTomography, Emission-Computed, Single-Photon4DCTcomputed tomographydeformable image registrationSPECTventilation

Identifiers

PMID33007118
PMCPMC7727923

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.