Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
3 citing papers in PubMed, 5 citations in OpenAlex.
- Intra-operative soft tissue perfusion assessment using X-ray angiography images: ischemic stroke study.Medical physics · 2026Article
- Volumetric soft tissue perfusion assessment on a region basis from x-ray angiography images: Motion compensation.Medical physics · 2025Article
- Intraprocedural C-arm dual-phase cone-beam enhancement patterns correlate with tumor absorbed dose after radioembolization.Medical physics · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
11 authors at 3 institutions in 1 country.
Funding
Abstract
purposeMany interventional procedures aim at changing soft tissue perfusion or blood flow. One problem at present is that soft tissue perfusion and its changes cannot be assessed in an interventional suite because cone-beam computed tomography is too slow (it takes 4-10 s per volume scan). In order to address the problem, we propose a novel method called IPEN for Intra-operative four-dimensional soft tissue PErfusion using a standard x-ray system with No gantry rotation.
methodsIPEN uses two input datasets: (a) the contours and locations of three-dimensional regions-of-interest (ROIs) such as arteries and sub-sections of cancerous lesions, and (b) a series of x-ray projection data obtained from an intra-arterial contrast injection to contrast enhancement to wash-out. IPEN then estimates a time-enhancement curve (TEC) for each ROI directly from projections without reconstructing cross-sectional images by maximizing the agreement between synthesized and measured projections with a temporal roughness penalty. When path lengths through ROIs are known for each x-ray beam, the ROI-specific enhancement can be accurately estimated from projections. Computer simulations are performed to assess the performance of the IPEN algorithm. Intra-arterial contrast-enhanced liver scans over 25 s were simulated using XCAT phantom version 2.0 with heterogeneous tissue textures and cancerous lesions. The following four sub-studies were performed: (a) The accuracy of the estimated TECs with overlapped lesions was evaluated at various noise (dose) levels with either homogeneous or heterogeneous lesion enhancement patterns; (b) the accuracy of IPEN with inaccurate ROI contours was assessed; (c) we investigated how overlapping ROIs and noise in projections affected the accuracy of the IPEN algorithm; and (d) the accuracy of the perfusion indices was assessed.
resultsThe TECs estimated by IPEN were sufficiently accurate at a reference dose level with the root-mean-square deviation (RMSD) of 0.0027 ± 0.0001 cm
conclusionThe IPEN algorithm can estimate ROI-specific TECs with high accuracy especially when 3 × 3 pixel averaging is applied, even when lesion enhancement is heterogeneous, or ROI contours are inaccurate but the SDC is at least 0.81.
Indexed as
Identifiers