Evidence map›Paper›PMID 33003536›Full record

ArticleSensors (Basel, Switzerland)2020

Feasibility Study of Precise Balloon Catheter Tracking and Visualization with Fast Photoacoustic Microscopy.

Jahae Kim, Thi Thao Mai, Jin Young Kim, Jung-Joon Min, Chulhong Kim, Changho Lee

Open access · goldAbstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
0.9field-weighted citation impact, top 29% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 13 citations in OpenAlex.

  1. Article
  2. Review
  3. Recent Advances in Imaging Sensors and Applications.Sensors (Basel, Switzerland) · 2021
    Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 3 institutions in 1 country.

Jahae KimDepartment of Nuclear Medicine, Chonnam National University Medical School & hospital, 42 Jebong-ro, Dong-gu, Gwangju 61469, Korea.
Thi Thao MaiDepartment of Artificial Intelligence Convergence, Chonnam National University, 77 Yongbong-ro, Buk-gu, Gwangju 61186, Korea.ORCID 0000-0003-3776-500X
Jin Young KimDepartments of Creative IT Engineering and Electrical Engineering, Pohang University of Science and Technology (POSTECH), 77 Cheongam-ro, Nam-gu, Pohang, Gyeongbuk-do 37673, Korea.
Jung-Joon MinDepartment of Nuclear Medicine, Chonnam National University Medical School & Hwasun Hospital, 264, Seoyang-ro, Hwasun-eup, Hwasun-gun, Jeollanam-do 58128, Korea.
Chulhong KimDepartments of Creative IT Engineering and Electrical Engineering, Pohang University of Science and Technology (POSTECH), 77 Cheongam-ro, Nam-gu, Pohang, Gyeongbuk-do 37673, Korea.ORCID 0000-0001-7249-1257
Changho LeeDepartment of Artificial Intelligence Convergence, Chonnam National University, 77 Yongbong-ro, Buk-gu, Gwangju 61186, Korea.ORCID 0000-0003-3560-0543
Chonnam National University · KRChonnam National University Hwasun Hospital · KRPohang University of Science and Technology · KR

Funding

Korea Health Technology R&D Project HI18C0858National Research Foundation 2017M3A9E8023017, 2017R1D1A1B03029556, 2019R1F1A1062948
6 · The paper itself

Abstract

Correct guiding of the catheter is a critical issue in almost all balloon catheter applications, including arterial stenosis expansion, coronary arterial diseases, and gastrointestinal tracking. To achieve safe and precise guiding of the balloon catheter, a novel imaging method with high-resolution, sufficient depth of penetration, and real-time display is required. Here, we present a new balloon catheter guiding method using fast photoacoustic microscopy (PAM) technique for precise balloon catheter tracking and visualization as a feasibility study. We implemented ex vivo and in vivo experiments with three different medium conditions of balloon catheter: no air, air, and water. Acquired cross-sectional, maximum amplitude projection (MAP), and volumetric 3D PAM images demonstrated its capability as a new imaging guiding tool for balloon catheter tracking and visualization.

Indexed as

CathetersMicroscopyPhotoacoustic TechniquesCross-Sectional StudiesFeasibility StudiesHumansballoon catheterimage guidingphotoacoustic imaging

Identifiers

PMID33003536
PMCPMC7582572
OpenAlexW3089507876

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.