Trial reportThe bone & joint journal2020
Vitamin E-doped total hip arthroplasty liners show similar head penetration to highly cross-linked polyethylene at five years: a multi-arm randomized controlled trial.
Trial report in The bone & joint journal, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 14 papers, 5 of them syntheses that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
14 citing papers in PubMed, 5 syntheses or guidelines pooled it, 38 citations in OpenAlex.
- Effects of macro- and micronutrient intake on bone mineral density, osteoporotic fracture risk, inflammation, and functional rehabilitation outcomes in orthopedic patients: a systematic review and meta-analysis.Frontiers in nutrition · 2026Pooled it
- The addition of vitamin E could reduce femoral head penetration of the polyethylene liners.Journal of orthopaedic surgery and research · 2025Pooled it
- Migration patterns of acetabular cups: a systematic review and meta-analysis of RSA studies.Acta orthopaedica · 2023Pooled it
- Risk factors for liner wear and head migration in total hip arthroplasty: a systematic review.Scientific reports · 2023Pooled it
- Vitamin E-Enhanced Liners in Primary Total Hip Arthroplasty: A Systematic Review and Meta-Analysis.BioMed research international · 2021Pooled it
- Vitamin E infused highly cross-linked cemented cups in total hip arthroplasty show good wear pattern and stabilize satisfactorily: a randomized, controlled RSA trial with 5-year follow-up.Acta orthopaedica · 2022Trial
- Article
- Measuring total hip arthroplasty liner wear using the EOS Imaging System: experimental and clinical results.Acta orthopaedica · 2024Article
- Article
- Safety of using a large femoral head on thin polyethylene for total hip arthroplasty based on different types of polyethylene.Scientific reports · 2023Article
- Head, acetabular liner composition, and rate of revision and wear in total hip arthroplasty: a Bayesian network meta-analysis.Scientific reports · 2023Article
- Review
- Ultra-High-Molecular-Weight Polyethylene in Hip and Knee Arthroplasties.Materials (Basel, Switzerland) · 2023Review
- Roentgen stereophotogrammetric analysis: still a very valuable tool in the orthopaedic research armamentarium.Bone & joint research · 2022Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
9 authors at 4 institutions in 2 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
aimsThe most frequent indication for revision surgery in total hip arthroplasty (THA) is aseptic loosening. Aseptic loosening is associated with polyethylene liner wear, and wear may be reduced by using vitamin E-doped liners. The primary objective of this study was to compare proximal femoral head penetration into the liner between a) two cross-linked polyethylene (XLPE) liners (vitamin E-doped (vE-PE)) versus standard XLPE liners, and b) two modular femoral head diameters (32 mm and 36 mm).
methodsPatients scheduled for a THA were randomized to receive a vE-PE or XLPE liner with a 32 mm or 36 mm metal head (four intervention groups in a 2 × 2 factorial design). Head penetration and acetabular component migration were measured using radiostereometric analysis at baseline, three, 12, 24, and 60 months postoperatively. The Harris Hip Score, University of California, Los Angeles (UCLA) Activity Score, EuroQol five-dimension questionnaire (EQ-5D), and 36-Item Short-Form Health Survey questionnaire (SF-36) were assessed at baseline, three, 12, 36, and 60 months.
resultsOf 220 screened patients, 127 were included in this study. In all, 116 received the allocated intervention, and 94 had their results analyzed at five years. Head penetration was similar between liner materials and head sizes at five years, vE-PE versus XLPE was -0.084 mm (95% confidence interval (CI) -0.173 to 0.005; p = 0.064), and 32 mm versus 36 mm was -0.020 mm (95% CI -0.110 to 0.071; p = 0.671), respectively. No differences were found in acetabular component migration or in the patient-reported outcome measures.
conclusionNo significant difference in head penetration was found at five years between vE-PE and XLPE liners, nor between 32 mm and 36 mm heads. Cite this article:
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.