Evidence map›Paper›PMID 32991783›Full record

ArticleJournal of applied clinical medical physics2020

Automatic segmentation and applicator reconstruction for CT-based brachytherapy of cervical cancer using 3D convolutional neural networks.

Daguang Zhang, Zhiyong Yang, Shan Jiang, Zeyang Zhou, Maobin Meng, Wei Wang

Abstract read
In one paragraph

Article in Journal of applied clinical medical physics, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 48 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
48citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

48 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Systematic review of artificial intelligence in brachytherapy.Journal of contemporary brachytherapy · 2026
    Review
  9. Article
  10. Article
  11. Article
  12. Article
  13. Article
  14. A review of artificial intelligence in brachytherapy.Journal of applied clinical medical physics · 2025
    Review
  15. Article
  16. Large language model-augmented learning for auto-delineation of treatment targets in head-and-neck cancer radiotherapy.Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology · 2025
    Article
  17. Article
  18. Review
  19. Review
  20. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Daguang ZhangSchool of Mechanical Engineering, Tianjin University, Tianjin, China.
Zhiyong YangSchool of Mechanical Engineering, Tianjin University, Tianjin, China.
Shan JiangSchool of Mechanical Engineering, Tianjin University, Tianjin, China.
Zeyang ZhouSchool of Mechanical Engineering, Tianjin University, Tianjin, China.
Maobin MengDepartment of Radiation Oncology, Tianjin Medical University Cancer Institute and Hospital, Tianjin, China.
Wei WangDepartment of Radiation Oncology, Tianjin Medical University Cancer Institute and Hospital, Tianjin, China.

Funding

National Natural Science Foundation of China 81872472
6 · The paper itself

Abstract

In this study, we present deep learning-based approaches to automatic segmentation and applicator reconstruction with high accuracy and efficiency in the planning computed tomography (CT) for cervical cancer brachytherapy (BT). A novel three-dimensional (3D) convolutional neural network (CNN) architecture was proposed and referred to as DSD-UNET. The dataset of 91 patients received CT-based BT of cervical cancer was used to train and test DSD-UNET model for auto-segmentation of high-risk clinical target volume (HR-CTV) and organs at risk (OARs). Automatic applicator reconstruction was achieved with DSD-UNET-based segmentation of applicator components followed by 3D skeletonization and polynomial curve fitting. Digitization of the channel paths for tandem and ovoid applicator in the planning CT was evaluated utilizing the data from 32 patients. Dice similarity coefficient (DSC), Jaccard Index (JI), and Hausdorff distance (HD) were used to quantitatively evaluate the accuracy. The segmentation performance of DSD-UNET was compared with that of 3D U-Net. Results showed that DSD-UNET method outperformed 3D U-Net on segmentations of all the structures. The mean DSC values of DSD-UNET method were 86.9%, 82.9%, and 82.1% for bladder, HR-CTV, and rectum, respectively. For the performance of automatic applicator reconstruction, outstanding segmentation accuracy was first achieved for the intrauterine and ovoid tubes (average DSC value of 92.1%, average HD value of 2.3 mm). Finally, HDs between the channel paths determined automatically and manually were 0.88 ± 0.12 mm, 0.95 ± 0.16 mm, and 0.96 ± 0.15 mm for the intrauterine, left ovoid, and right ovoid tubes, respectively. The proposed DSD-UNET method outperformed the 3D U-Net and could segment HR-CTV, bladder, and rectum with relatively good accuracy. Accurate digitization of the channel paths could be achieved with the DSD-UNET-based method. The proposed approaches could be useful to improve the efficiency and consistency of treatment planning for cervical cancer BT.

Indexed as

BrachytherapyUterine Cervical NeoplasmsFemaleHumansImage Processing, Computer-AssistedNeural Networks, ComputerOrgans at RiskTomography, X-Ray Computedautomatic segmentationbrachytherapycervical cancerconvolutional neural networks

Identifiers

PMID32991783
PMCPMC7592978

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.