Evidence map›Paper›PMID 32990139›Full record

ArticleJournal of the International Association of Providers of AIDS Care

From Sequence Data to Patient Result: A Solution for HIV Drug Resistance Genotyping With Exatype, End to End Software for Pol-HIV-1 Sanger Based Sequence Analysis and Patient HIV Drug Resistance Result Generation.

Leonard Kingwara, Muthoni Karanja, Catherine Ngugi, Geoffrey Kangogo, Kipkerich Bera, Maureen Kimani, Nancy Bowen, Dorcus Abuya, Violet Oramisi, Irene Mukui

Abstract read
In one paragraph

Article in Journal of the International Association of Providers of AIDS Care. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Review
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Leonard KingwaraNational Public Health Laboratory (NPHL), Nairobi, Kenya.ORCID 0000-0001-5382-8053
Muthoni KaranjaNational AIDS and STI Control Program (NASCOP), Nairobi, Kenya.
Catherine NgugiNational AIDS and STI Control Program (NASCOP), Nairobi, Kenya.
Geoffrey KangogoNational Public Health Laboratory (NPHL), Nairobi, Kenya.
Kipkerich BeraNational Public Health Laboratory (NPHL), Nairobi, Kenya.
Maureen KimaniNational AIDS and STI Control Program (NASCOP), Nairobi, Kenya.
Nancy BowenNational Public Health Laboratory (NPHL), Nairobi, Kenya.
Dorcus AbuyaNational Public Health Laboratory (NPHL), Nairobi, Kenya.
Violet OramisiNational AIDS and STI Control Program (NASCOP), Nairobi, Kenya.
Irene MukuiNational AIDS and STI Control Program (NASCOP), Nairobi, Kenya.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionWith the rapid scale-up of antiretroviral therapy (ART) to treat HIV infection, there are ongoing concerns regarding probable emergence and transmission of HIV drug resistance (HIVDR) mutations. This scale-up has to lead to an increased need for routine HIVDR testing to inform the clinical decision on a regimen switch. Although the majority of wet laboratory processes are standardized, slow, labor-intensive data transfer and subjective manual sequence interpretation steps are still required to finalize and release patient results. We thus set out to validate the applicability of a software package to generate HIVDR patient results from raw sequence data independently.

methodsWe assessed the performance characteristics of Hyrax Bioscience's Exatype (a sequence data to patient result, fully automated sequence analysis software, which consolidates RECall, MEGA X and the Stanford HIV database) against the standard method (RECall and Stanford database). Exatype is a web-based HIV Drug resistance bioinformatic pipeline available at sanger.exatype.com. To validate the exatype, we used a test set of 135 remnant HIV viral load samples at the National HIV Reference Laboratory (NHRL).

resultWe analyzed, and successfully generated results of 126 sequences out of 135 specimens by both Standard and Exatype software. Result production using Exatype required minimal hands-on time in comparison to the Standard (6 computation-hours using the standard method versus 1.5 Exatype computation-hours). Concordance between the 2 systems was 99.8% for 311,227 bases compared. 99.7% of the 0.2% discordant bases, were attributed to nucleotide mixtures as a result of the sequence editing in Recall. Both methods identified similar (99.1%) critical antiretroviral resistance-associated mutations resulting in a 99.2% concordance of resistance susceptibility interpretations. The Base-calling comparison between the 2 methods had Cohen's kappa (0.97 to 0.99), implying an almost perfect agreement with minimal base calling variation. On a predefined dataset, RECall editing displayed the highest probability to score mixtures accurately 1 vs. 0.71 and the lowest chance to inaccurately assign mixtures to pure nucleotides (0.002-0.0008). This advantage is attributable to the manual sequence editing in RECall.

conclusionThe reduction in hands-on time needed is a benefit when using the Exatype HIV DR sequence analysis platform and result generation tool. There is a minimal difference in base calling between Exatype and standard methods. Although the discrepancy has minimal impact on drug resistance interpretation, allowance of sequence editing in Exatype as RECall can significantly improve its performance.

Indexed as

SoftwareAnti-HIV AgentsDrug Resistance, ViralGenotypeHIV-1HIV InfectionsHumansMutationReproducibility of ResultsSequence AnalysisViral LoadAnti-HIV Agentsdrug resistance testingefficiency and resultsvalidation

Identifiers

PMID32990139
PMCPMC7536479

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.