Evidence map›Paper›PMID 32986780›Full record

ArticlePloS one2020

Resting TcPO2 levels decrease during liner wear in persons with a transtibial amputation.

Martin C Berli, Michèle Jundt-Ecker, Margrit R Meier, Michael Hofer, Madlaina Schöni, Tobias Götschi, Ilker Uçkay, Thomas Böni, Felix W A Waibel

Abstract read
In one paragraph

Article in PloS one, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Martin C BerliDepartment of Orthopaedic Surgery, Balgrist University Hospital, Zurich, Switzerland.
Michèle Jundt-EckerDepartment of Orthopaedic Surgery, Balgrist University Hospital, Zurich, Switzerland.
Margrit R MeierConReha GmbH, Buttikon, Switzerland.
Michael HoferRehaklinik Bellikon, Bellikon, Switzerland.
Madlaina SchöniDepartment of Orthopaedic Surgery, Balgrist University Hospital, Zurich, Switzerland.
Tobias GötschiDepartment of Orthopaedic Surgery, Institute for Biomechanics, University of Zurich, ETH Zurich, Balgrist Campus, Zurich, Switzerland.
Ilker UçkayDepartment of Orthopaedic Surgery, Balgrist University Hospital, Zurich, Switzerland.ORCID 0000-0002-5552-0973
Thomas BöniDepartment of Orthopaedic Surgery, Balgrist University Hospital, Zurich, Switzerland.
Felix W A WaibelDepartment of Orthopaedic Surgery, Balgrist University Hospital, Zurich, Switzerland.ORCID 0000-0003-3991-8743

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundIn our clinic, a substantial number of patients present with transtibial residual limb pain of no specific somatic origin. Silicone liner induced tissue compression may reduce blood flow, possibly causing residual limb pain. Thus, as a first step we investigated if the liner itself has an effect on transcutaneous oxygen pressure (TcPO2).

methodsPersons with unilateral transtibial amputation and residual limb pain of unknown origin were included. Medical history, including residual limb pain, was recorded, and the SF-36 administered. Resting TcPO2 levels were measured in the supine position and without a liner at 0, 10, 20 and 30 minutes using two sensors: one placed in the Transverse plane over the tip of the Tibia End (= TTE), the other placed in the Sagittal plane, distally over the Peroneal Compartment (= SPC). Measurements were repeated with specially prepared liners avoiding additional pressure due to sensor placement. Statistical analyses were performed using SPSS.

resultsTwenty persons (9 women, 11 men) with a mean age of 68.65 years (range 47-86 years) participated. The transtibial amputation occurred on average 43 months prior to study entry (range 3-119 months). With liner wear, both sensors measured TcPO2 levels that were significantly lower than those measured without a liner (TTE: p < 0.001; SPC: p = 0.002) after 10, 20 and 30 minutes. No significant differences were found between TcPO2 levels over time between the sensors. There were no significant associations between TcPO2 levels and pain, smoking status, age, duration of daily liner use, mobility level, and revision history.

conclusionResting TcPO2 levels decreased significantly while wearing a liner alone, without a prosthetic socket. Further studies are required to investigate the effect of liner wear on exercise TcPO2 levels.

Indexed as

Amputation, SurgicalRestAgedAged, 80 and overAge FactorsAmputation StumpsBlood Gas Monitoring, TranscutaneousFemaleHumansMaleMiddle AgedPeripheral Arterial DiseasePhantom LimbSex FactorsSiliconesTibiaSilicones

Identifiers

PMID32986780
PMCPMC7521692

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.