ArticlePloS one2020

Test-retest reliability of the Performance of Upper Limb (PUL) module for muscular dystrophy patients.

Marta Gandolla, Alberto Antonietti, Valeria Longatelli, Emilia Biffi, Eleonora Diella, Morena Delle Fave, Mauro Rossini, Franco Molteni, Grazia D'Angelo, Marco Bocciolone and 1 more

Open access · goldAbstract read
In one paragraph

Article in PloS one, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers.

0numbers the graph read from it
0cells of the map it votes in
12citing papers in PubMed
0.6field-weighted citation impact, top 34% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

12 citing papers in PubMed, 22 citations in OpenAlex.

  1. Trial
  2. Trial
  3. Article
  4. Article
  5. Article
  6. Article
  7. Review
  8. Article
  9. Article
  10. Article
  11. The Performance of Upper Limb (PUL) module in limb-girdle muscular dystrophy.Acta myologica : myopathies and cardiomyopathies : official journal of the Mediterranean Society of Myology · 2022
    Article
  12. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors at 3 institutions in 1 country.

Marta GandollaNearlab, Department of Electronics, Information and Bioengineering, Politecnico di Milano, Milano, Italy.ORCID 0000-0001-5237-714X
Alberto AntoniettiNearlab, Department of Electronics, Information and Bioengineering, Politecnico di Milano, Milano, Italy.ORCID 0000-0003-0388-6321
Valeria LongatelliNearlab, Department of Electronics, Information and Bioengineering, Politecnico di Milano, Milano, Italy.ORCID 0000-0001-5327-066X
Emilia BiffiScientific Institute IRCCS E. Medea, Bosisio Parini, Italy.
Eleonora DiellaScientific Institute IRCCS E. Medea, Bosisio Parini, Italy.
Morena Delle FaveScientific Institute IRCCS E. Medea, Bosisio Parini, Italy.
Mauro RossiniVilla Beretta Rehabilitation Center, Valduce Hospital, Costa Masnaga, Italy.ORCID 0000-0002-7670-5758
Franco MolteniVilla Beretta Rehabilitation Center, Valduce Hospital, Costa Masnaga, Italy.
Grazia D'AngeloScientific Institute IRCCS E. Medea, Bosisio Parini, Italy.
Marco BoccioloneDepartment of Mechanical Engineering, Politecnico di Milano, Milano, Italy.
Alessandra PedrocchiNearlab, Department of Electronics, Information and Bioengineering, Politecnico di Milano, Milano, Italy.
Politecnico di Milano · ITIRCCS Eugenio Medea · ITOspedale Valduce · IT

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The Performance of the Upper Limb (PUL) module is an externally-assessed clinical scale, initially designed for the Duchenne muscular dystrophy population. It provides an upper extremity functional score suitable for both weaker ambulatory and non-ambulatory phases up to the severely impaired patients. It is capable of characterizing overall progression and severity of disease and of tracking the stereotypical proximal-to-distal progressive loss of upper limb function in muscular dystrophy. Since the PUL module has been validated only with Duchenne patients, its use also for Becker and Limb-Girdle muscular dystrophy patients has been here evaluated, to verify its reliability and extend its use. In particular, two different assessors performed this scale on 32 dystrophic subjects in two consecutive days. The results showed that the PUL module has high reliability, both absolute and relative, based on the calculation of Pearson's r (0.9942), Intraclass Correlation Coefficient (0.9943), Standard Error of Measurement (1.36), Minimum Detectable Change (3.77), and Coefficient of Variation (3%). The Minimum Detectable Change, in particular, can be used in clinical trials to perform a comprehensive longitudinal evaluation of the effects of interventions with the lapse of time. According to this analysis, an intervention is effective if the difference in the PUL score between subsequent evaluation points is equal or higher than 4 points; otherwise, the observed effect is not relevant. Inter-rater reliability with ten different assessors was evaluated, and it has been demonstrated that deviation from the mean is lower than calculated Minimum Detectable Change. The present work provides evidence that the PUL module is a reliable and valid instrument for measuring upper limb ability in people with different forms of muscular dystrophy. Therefore, the PUL module might be extended to other pathologies and reliably used in multicenter settings.

Indexed as

AdolescentAdultDiagnostic Techniques and ProceduresDisease ProgressionHumansMuscular Dystrophy, DuchenneReproducibility of ResultsUpper ExtremityYoung Adult

Identifiers

PMID32986757
PMCPMC7521751
OpenAlexW3090397284

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.