Evidence map›Paper›PMID 32983548›Full record

ArticleHealthcare technology letters2020

Baseline wander and power-line interference elimination of ECG signals using efficient signal-piloted filtering.

Saeed Mian Qaisar

Abstract read
In one paragraph

Article in Healthcare technology letters, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed.

  1. Review
  2. Reducing False Alarm Rates and Workload in ICUs by Improving Arrhythmia Detection Algorithms of Patient Monitoring Systems.Medical science monitor : international medical journal of experimental and clinical research · 2025
    Article
  3. Review
  4. Article
  5. Article
  6. Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

1 author.

Saeed Mian QaisarDepartment of Electrical and Computer Engineering, EFfat University, Jeddah, 21478, Kingdom of Saudi Arabia.ORCID 0000-0002-4268-3482

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

A signal-piloted linear phase filtering tactic for removing baseline wander and power-line interference from the electrocardiogram (ECG) signals is suggested. The system is capable of adjusting its parameters by following the incoming signal variations. It renders the processing of lesser samples by inferior order filters. The applicability is demonstrated by using the MIT-BIH ECG database. The precision of the approach is also studied regarding the signal-to-noise ratio (SNR). Results showed that the proposed method achieves a 2.18-fold compression gain and notable computational efficiency over conventional counterpart while securing an analogous output SNR. A comparison of the designed solution is made with the contemporary empirical mode decomposition with Kalman filtering and eigenvalue decomposition based tactics. Results show that the suggested method performs better in terms of output SNR for the studied cases.

Indexed as

2.18-fold compression gainanalogous output SNRbaseline wander interference eliminationcomputational efficiencyECG signalseigenvalue decomposition based tacticselectrocardiogram signalselectrocardiographyfiltering theoryinferior order filtersmedical signal processingMIT-BIH ECG databasepower-line interference eliminationsignal-piloted linear phase filtering tacticssignal-to-noise ratiosignal variations

Identifiers

PMID32983548
PMCPMC7494370

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.