Evidence map›Paper›PMID 32982607›Full record

ArticleJournal of interventional cardiology2020

Microtransesophageal Echocardiographic Guidance during Percutaneous Interatrial Septal Closure without General Anaesthesia.

Roel J R Snijder, Laura E Renes, Martin J Swaans, Maarten Jan Suttorp, Jurrien M Ten Berg, Martijn C Post

Open access · goldAbstract read
In one paragraph

Article in Journal of interventional cardiology, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed, 1 pooled it
0.6field-weighted citation impact, top 27% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 1 synthesis or guideline pooled it, 11 citations in OpenAlex.

  1. Pooled it
  2. Review
  3. Interventions for adult congenital heart disease.Nature reviews. Cardiology · 2025
    Review
  4. Article
  5. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 1 institution in 1 country.

Roel J R SnijderDepartment of Cardiology, St. Antonius Hospital, Nieuwegein, Netherlands.ORCID https://orcid.org/0000-0003-2246-0617
Laura E RenesDepartment of Emergency Medicine, St. Antonius Hospital, Nieuwegein, Netherlands.
Martin J SwaansDepartment of Cardiology, St. Antonius Hospital, Nieuwegein, Netherlands.
Maarten Jan SuttorpDepartment of Cardiology, St. Antonius Hospital, Nieuwegein, Netherlands.
Jurrien M Ten BergDepartment of Cardiology, St. Antonius Hospital, Nieuwegein, Netherlands.
Martijn C PostDepartment of Cardiology, St. Antonius Hospital, Nieuwegein, Netherlands.
St. Antonius Ziekenhuis · NL

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveTo study the safety and efficacy of microtransesophageal echocardiography (micro-TEE) and TEE during percutaneous atrial septal defect (ASD) and patent foramen ovale (PFO) closure.

backgroundTEE has proven to be safe during ASD and PFO closure under general anaesthesia. Micro-TEE makes it possible to perform these procedures under local anaesthesia. We are the first to describe the safety and efficacy of micro-TEE for percutaneous closure.

methodsAll consecutive patients who underwent ASD and PFO closure between 2013 and 2018 were included. The periprocedural complications were registered. Residual shunts were diagnosed using transthoracic contrast echocardiography (TTCE). All data were compared between the use of TEE or micro-TEE within the ASD and PFO groups separately.

resultsIn total, 82 patients underwent ASD closure, 46 patients (49.1 ± 15.0 years) with TEE and 36 patients (47.8 ± 12.1 years) using micro-TEE guidance. Median device diameter was, respectively, 26 mm (range 10-40 mm) and 27 mm (range 10-35 mm). PFO closure was performed in 120 patients, 55 patients (48.6 ± 9.2 years, median device diameter 25 mm, range 23-35 mm) with TEE and 65 patients (mean age 51.0 ± 11.8 years, median device diameter 27 mm, range 23-35 mm) using micro-TEE. There were no major periprocedural complications, especially no device embolizations within all groups. Six months after closure, there was no significant difference in left-to-right shunt after ASD closure and no significant difference in right-to-left shunt after PFO closure using TEE or micro-TEE.

conclusionMicro-TEE guidance without general anaesthesia during percutaneous ASD and PFO closure is as safe as TEE, without a significant difference in the residual shunt rate after closure.

Indexed as

Prosthesis ImplantationSeptal Occluder DeviceCardiac CatheterizationEchocardiography, TransesophagealFemaleHeart Septal Defects, AtrialHumansMaleMiddle AgedSurgery, Computer-AssistedTreatment Outcome

Identifiers

PMID32982607
PMCPMC7492935
OpenAlexW3084021931

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.