ArticleEuropean archives of oto-rhino-laryngology : official journal of the European Federation of Oto-Rhino-Laryngological Societies (EUFOS) : affiliated with the German Society for Oto-Rhino-Laryngology - Head and Neck Surgery2021
The ability of the eating assessment tool-10 to detect penetration and aspiration in Parkinson's disease.
Article in European archives of oto-rhino-laryngology : official journal of the European Federation of Oto-Rhino-Laryngological Societies (EUFOS) : affiliated with the German Society for Oto-Rhino-Laryngology - Head and Neck Surgery, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
9 citing papers in PubMed, 14 citations in OpenAlex.
- Breathe, Eat, Talk: Three Essential Ingredients to Quality-of-Life Outcomes in Movement Disorders.Movement disorders clinical practice · 2026Review
- Review
- Review
- Article
- Validation and Reliability of the Polish Version of the Eating Assessment Tool-10 Questionnaire.Nutrients · 2025Article
- Sensitivity and specificity of the EAT-10 and SDQ-DP in identifying the risk of dysphagia in Parkinson's disease.Arquivos de neuro-psiquiatria · 2024Article
- Is the ability of the Eating Assessment Tool (EAT-10) to screen for aspiration in patients with dysphagia depending on the patients' disease?European archives of oto-rhino-laryngology : official journal of the European Federation of Oto-Rhino-Laryngological Societies (EUFOS) : affiliated with the German Society for Oto-Rhino-Laryngology - Head and Neck Surgery · 2022Article
- Is the ability of the Eating Assessment Tool (EAT-10) to screen for aspiration in patients with dysphagia depending on the patients' disease?European archives of oto-rhino-laryngology : official journal of the European Federation of Oto-Rhino-Laryngological Societies (EUFOS) : affiliated with the German Society for Oto-Rhino-Laryngology - Head and Neck Surgery · 2022Article
- Relationship Between EAT-10 Scores, Pharyngeal Residue Severity, and Penetration-Aspiration in Individuals With Idiopathic Parkinson's Disease: A FEES-Based Correlation and Discriminative Performance Study.International journal of language & communication disordersArticle
Corrections and comments
- Commented on by
Authors and funding
11 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
purposeDysphagia is common in patients with Parkinson's disease (PD) and often leads to pneumonia, malnutrition, and reduced quality of life. This study investigates the ability of the Eating Assessment Tool-10 (EAT-10), an established, easy self-administered screening tool, to detect aspiration in PD patients. This study aims to validate the ability of the EAT-10 to detect FEES-proven aspiration in patients with PD.
methodsIn a controlled prospective cross-sectional study, a total of 50 PD patients completed the EAT-10 and, subsequently, were examined by Flexible Endoscopic Evaluation of Swallowing (FEES) to determine the swallowing status. The results were rated through the Penetration-Aspiration Scale (PAS) and data were analyzed retrospectively.
resultsPAS and EAT-10 did not correlate significantly. Selected items of the EAT-10 could not predict aspiration or residues. 19 (38%) out of 50 patients with either penetration or aspiration were not detected by the EAT-10. The diagnostic accuracy was established at only a sufficient level (AUC 0.65). An optimal cut-off value of ≥ 6 presented a sensitivity of 58% and specificity of 82%.
conclusionsThe EAT-10 is not suited for the detection of penetration and aspiration in PD patients. Therefore, it cannot be used as a screening method in this patient population. There is still a need for a valid, simple, and efficient screening tool to assist physicians in their daily diagnostics and to avoid clinical complications.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.