ArticleEuropean heart journal. Case reports2020
A case report of simultaneous His pacemaker implantation and atrioventricular junction ablation following unsuccessful treatment of atrial fibrillation.
Article in European heart journal. Case reports, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed, 1 citations in OpenAlex.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundAtrial fibrillation can contribute to heart failure. Frequently, rhythm control is unachievable. Atrioventricular (AV) junction ablation and pacemaker implantation remain to be a therapeutic option for rate control in atrial fibrillation. Interventricular asynchrony is a potential downside of right ventricular pacing. However, cardiac resynchronization therapy and His pacing restore physiological activation sequences of the ventricles. CASE SUMMARY: The reported patient had undergone several interventions to cure atrial fibrillation without sufficient rhythm control and experienced deleterious effects of recurrent arrhythmias. Finally, we decided to ablate the AV junction simultaneously with the implantation of a His bundle pacemaker. Atrioventricular junction ablation had to be repeated following conduction recurrence. A left-sided transaortic approach was required to create a permanent effect and to avoid distal lesions. His pacing was not affected by the AV junction ablation at all. The pre-existing widened QRS was normalized by His pacing, the patient became free of any complaints with full restoration of exertion capability. DISCUSSION: His pacing has the potential to contribute to a revival of the 'ablate-and-pace' concept for incurable atrial fibrillation by restoring physiological ventricular activation, thereby overcoming the particular drawbacks of continuous ventricular pacing. Atrioventricular junction ablation simultaneously with the pacemaker implantation procedure is safe and feasible. His pacing is at least an alternative for cardiac resynchronization therapy. The implantation procedure is sometimes challenging.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.