ArticleMagnetic resonance in medicine2021
Dynamic distortion correction for functional MRI using FID navigators.
Article in Magnetic resonance in medicine, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 16 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
16 citing papers in PubMed, 23 citations in OpenAlex.
- ISME-incoherent sampling of multi-echo data to minimize cardiac-induced noise in brain maps ofMagnetic resonance in medicine · 2026Article
- A closer look: pediatric neuroimaging at 7T.Pediatric radiology · 2025Review
- Chemical shift-encoded multishot EPI for navigator-free prostate DWI.Magnetic resonance in medicine · 2025Article
- Dynamic field mapping and distortion correction using single-shot blip-rewound EPI and joint multi-echo reconstruction.Magnetic resonance in medicine · 2024Article
- Rapid motion estimation and correction using self-encoded FID navigators in 3D radial MRI.Magnetic resonance in medicine · 2024Article
- Advancements in MR hardware systems and magnetic field control: BPsychoradiology · 2024Review
- Combining the benefits of 3D acquisitions and spiral readouts for VASO fMRI at UHF.Imaging neuroscience (Cambridge, Mass.) · 2024Article
- Dynamic off-resonance correction improves functional image analysis in fMRI of awake behaving non-human primates.Frontiers in neuroimaging · 2024Article
- Distortion correction using topup algorithm by single k-space (TASK) for echo planar imaging.Scientific reports · 2023Article
- Improved dynamic distortion correction for fMRI using single-echo EPI and a readout-reversed first image (REFILL).Human brain mapping · 2023Article
- Article
- Prediction of motion induced magnetic fields for human brain MRI at 3 T.Magma (New York, N.Y.) · 2023Article
- Off-resonance artifact correction for MRI: A review.NMR in biomedicine · 2023Review
- Real-time shimming with FID navigators.Magnetic resonance in medicine · 2022Article
- Model-based dynamic off-resonance correction for improved accelerated fMRI in awake behaving nonhuman primates.Magnetic resonance in medicine · 2022Article
- High-resolution fMRI at 7 Tesla: challenges, promises and recent developments for individual-focused fMRI studies.Current opinion in behavioral sciences · 2021Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors at 4 institutions in 2 countries.
Funding
Abstract
purposeTo develop a method for slice-wise dynamic distortion correction for EPI using rapid spatiotemporal B
methodsA low-resolution reference image was used to create a forward model of FIDnav signal changes to enable estimation of spatiotemporal B
resultsField inhomogeneity coefficients and voxel shift maps measured using FIDnavs were in excellent agreement with multi-echo EPI measurements. The FID-navigated distortion correction accurately corrected image geometry in the presence of induced magnetic field perturbations, outperforming the data-driven approach in regions with large field offsets. In functional MRI scans with nose touching, FIDnav-based correction yielded temporal SNR gains of 30% in gray matter. Following image realignment, which accounted for global image shifts, temporal SNR gains of 3% were achieved.
conclusionsOur proposed application of FIDnavs enables slice-wise dynamic distortion correction with high temporal efficiency. We achieved improved signal stability by leveraging the encoding information from multichannel coils. This approach can be easily adapted to other EPI-based sequences to improve temporal SNR for a variety of clinical and research applications.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials