Evidence map›Paper›PMID 32970558›Full record

Trial reportThe western journal of emergency medicine2020

Barrier Enclosure for Endotracheal Intubation in a Simulated COVID-19 Scenario: A Crossover Study.

Torrey A Laack, Franziska Pollok, Benjamin J Sandefur, Aidan F Mullan, Christopher S Russi, Suraj M Yalamuri

Open access · goldAbstract readRandomized Controlled Trial
In one paragraph

Trial report in The western journal of emergency medicine, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
3.3field-weighted citation impact, top 7% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed, 14 citations in OpenAlex.

  1. Trial
  2. Trial
  3. Article
  4. Article
  5. Article
  6. A new device for bronchoscopy for better protection.Turkish journal of medical sciences · 2022
    Article
  7. Article
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 3 institutions in 1 country.

Torrey A LaackMayo Clinic, Department of Emergency Medicine, Rochester, Minnesota.
Franziska PollokMayo Clinic, Mayo Clinic Multidisciplinary Simulation Center, Rochester, Minnesota.
Benjamin J SandefurMayo Clinic, Department of Emergency Medicine, Rochester, Minnesota.
Aidan F MullanMayo Clinic, Division of Biomedical Statistics and Informatics, Rochester, Minnesota.
Christopher S RussiMayo Clinic, Department of Emergency Medicine, Rochester, Minnesota.
Suraj M YalamuriMayo Clinic, Department of Anesthesiology, Rochester, Minnesota.
Mayo Clinic · USMayo Clinic in Florida · USWinnMed · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionBarrier enclosures have been developed to reduce the risk of COVID-19 transmission to healthcare providers during intubation, but little is known about their impact on procedure performance. We sought to determine whether a barrier enclosure delays time to successful intubation by experienced airway operators.

methodsWe conducted a crossover simulation study at a tertiary academic hospital. Participants watched a four-minute video, practiced one simulated intubation with a barrier enclosure, and then completed one intubation with and one without the barrier enclosure (randomized to determine order). The primary outcome measure was time from placement of the video laryngoscope at the lips to first delivered ventilation. Secondary outcomes were periprocedural complications and participant responses to a post-study survey.

resultsProceduralists (n = 50) from emergency medicine and anesthesiology had median intubation times of 23.6 seconds with practice barrier enclosure, 20.5 seconds with barrier enclosure, and 16.7 seconds with no barrier. Intubation with barrier enclosure averaged 4.5 seconds longer (95% confidence interval, 2.7-6.4, p < .001) than without, but was less than the predetermined clinical significance threshold of 10 seconds. Three complications occurred, all during the practice intubation. Barrier enclosure made intubation more challenging according to 48%, but 90% indicated they would consider using it in clinical practice.

conclusionExperienced airway operators performed intubation using a barrier enclosure with minimal increased time to procedure completion in this uncomplicated airway model. Given potential to reduce droplet spread, use of a barrier enclosure may be an acceptable adjunct to endotracheal intubation for those familiar with its use.

Indexed as

BetacoronavirusAdultAnesthesiologyClinical CompetenceCoronavirus InfectionsCOVID-19Cross-Over StudiesEmergency MedicineFemaleHumansInfectious Disease Transmission, Patient-to-ProfessionalIntubation, IntratrachealLaryngoscopesMaleManikinsPandemics

Identifiers

PMID32970558
PMCPMC7514393
OpenAlexW3083842326

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.