Evidence map›Paper›PMID 32967710›Full record

ArticleJournal of orthopaedic surgery and research2020

Evaluation of three-dimensional acromiohumeral distance in the standing position and comparison with its conventional measuring methods.

Yuki Yoshida, Noboru Matsumura, Yoshitake Yamada, Minoru Yamada, Yoichi Yokoyama, Morio Matsumoto, Masaya Nakamura, Takeo Nagura, Masahiro Jinzaki

Registry-linked trialOpen access · goldAbstract readComparative Study
In one paragraph

Article in Journal of orthopaedic surgery and research, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT04759027 (Prospective Evaluation of the Reliability and Re-applicability of Subacromial Distance Measurement With Standard Radiographic Imaging Compared to Ultrasound Imaging), which is not on this map. Cited by 13 papers.

0numbers the graph read from it
0cells of the map it votes in
13citing papers in PubMed
2.5field-weighted citation impact, top 10% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT04759027 completednot on this mapstarted 2021, after this paper: background citation

Prospective Evaluation of the Reliability and Re-applicability of Subacromial Distance Measurement With Standard Radiographic Imaging Compared to Ultrasound Imaging

TypeobservationalSponsorGöker Utku değerRan2021 to 2022Enrolled56ConditionsSubacromial Impingement, Rotator Cuff TearsArmssubacromial distance measurement
3 · Its place in the literature

Who cites it

13 citing papers in PubMed, 16 citations in OpenAlex.

  1. Review
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. [Comparison of the effectiveness of the long head of the biceps tendon with or without proximal amputation after arthroscopic repair of the rotator cuff].Zhongguo xiu fu chong jian wai ke za zhi = Zhongguo xiufu chongjian waike zazhi = Chinese journal of reparative and reconstructive surgery · 2022
    Article
  13. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 2 institutions in 1 country.

Yuki YoshidaDepartment of Orthopedic Surgery, Keio University School of Medicine, 35 Shinanomachi, Shinjuku-ku, Tokyo, 160-8582, Japan.
Noboru MatsumuraDepartment of Orthopedic Surgery, Keio University School of Medicine, 35 Shinanomachi, Shinjuku-ku, Tokyo, 160-8582, Japan. noboru18@gmail.com.ORCID http://orcid.org/0000-0001-7629-0241
Yoshitake YamadaDepartment of Radiology, Keio University School of Medicine, 35 Shinanomachi, Shinjuku-ku, Tokyo, 160-8582, Japan. yamada@rad.med.keio.ac.jp.
Minoru YamadaDepartment of Radiology, Keio University School of Medicine, 35 Shinanomachi, Shinjuku-ku, Tokyo, 160-8582, Japan.
Yoichi YokoyamaDepartment of Radiology, Keio University School of Medicine, 35 Shinanomachi, Shinjuku-ku, Tokyo, 160-8582, Japan.
Morio MatsumotoDepartment of Orthopedic Surgery, Keio University School of Medicine, 35 Shinanomachi, Shinjuku-ku, Tokyo, 160-8582, Japan.
Masaya NakamuraDepartment of Orthopedic Surgery, Keio University School of Medicine, 35 Shinanomachi, Shinjuku-ku, Tokyo, 160-8582, Japan.
Takeo NaguraDepartment of Orthopedic Surgery, Keio University School of Medicine, 35 Shinanomachi, Shinjuku-ku, Tokyo, 160-8582, Japan.
Masahiro JinzakiDepartment of Radiology, Keio University School of Medicine, 35 Shinanomachi, Shinjuku-ku, Tokyo, 160-8582, Japan.
Keio University · JPKeio University Hospital · JP

Funding

Japan Society for the Promotion of Science 17H04266Japan Society for the Promotion of Science 17K16482Japan Society for the Promotion of Science 20K08056
6 · The paper itself

Abstract

backgroundNarrowing of the acromiohumeral distance (AHD) implies a rotator cuff tear. However, conventional AHD measurements using two-dimensional (2D) imaging or with the patient in the supine position might differ from that while standing during daily activity. This study aimed to evaluate the three-dimensional (3D) actual distance between the acromion and humeral head in the standing position and compare the AHD values with those obtained using conventional measuring methods.

methodsComputed tomography (CT) images of 166 shoulders from 83 healthy volunteers (31 male and 52 female; mean age 40.1 ± 5.8 years; age range, 30-49 years) were prospectively acquired in the supine and standing positions using conventional and upright CT scanners, respectively. The minimum distance between the acromion and humeral head on the 3D surface models was considered as the 3D AHD. We measured the 2D AHD on anteroposterior digitally reconstructed radiographs. The AHD values were compared between the supine and standing positions and between the 2D and 3D measurements.

resultsThe mean values of 2D AHD were 8.8 ± 1.3 mm (range, 5.9-15.4 mm) in the standing position and 8.1 ± 1.2 mm (range, 5.3-14.3 mm) in the supine position. The mean values of 3D AHD were 7.3 ± 1.4 mm (range, 4.7-14.0 mm) in the standing position and 6.6 ± 1.2 mm (range, 4.4-13.7 mm) in the supine position. The values of 3D AHD were significantly lower than those of 2D AHDs in both the standing and supine positions (P < 0.001). The values of 2D and 3D AHDs were significantly lower in the supine position than in the standing position (P < 0.001).

conclusionsThis study evaluated the 3D AHD of normal shoulders in the standing position using an upright CT scanner. The present results indicated that assessments in the supine position can underestimate the value of the AHD compared with those made in the standing position and that assessments using 2D analysis can overestimate the value.

Indexed as

Standing PositionAcromionAdultFemaleHealthy VolunteersHumansHumeral HeadImaging, Three-DimensionalMaleMiddle AgedProspective StudiesSupine PositionTomography, X-Ray ComputedAcromiohumeral distanceAcromiohumeral intervalDigitally reconstructed radiographsNormal shoulderPositionUpright computed tomography

Identifiers

PMID32967710
PMCPMC7510276
OpenAlexW3089061135

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.